远程随访在埋藏式心脏转复除颤器患者随访中的应用进展
摘要
埋藏式心脏转复除颤器(ICD)误放电是ICD临床应用中时常困扰的问题,将远程随访技术应用于ICD患者的随访是安全的,而且能够更早发现临床事件,缩短临床决策时间,最终起到减少ICD误放电的作用。
出处
《中国心脏起搏与心电生理杂志》
2016年第2期149-150,共2页
Chinese Journal of Cardiac Pacing and Electrophysiology
参考文献10
-
1Dubner S, Auricchio A, Steinberg JS, et al. ISHNE/EHRA ex pert consensus on remote monitoring of cardiovascular implant able electronic devices (CIEDs) [J]. Europace, 2012,14 (2) 278.
-
2孙宝贵,张锋,刘少稳.植入性心脏电器械的远程监测系统[J].中国心脏起搏与心电生理杂志,2011,25(6):478-481. 被引量:3
-
3Saxon LA, Hayes DL, Gilliam FR, et al. Long-term outcome after ICD and CRT implantation and influence of remote device follow-up~ The ALTITUDE survival study [J]. Cireulation, 2010,122:2 359.
-
4曾治宇,于鹏,张逸群,徐志武.真实世界的精彩——来自ALTITUDE临床科学项目的启示[J].中国心脏起搏与心电生理杂志,2013,27(1):5-7. 被引量:3
-
5Varma N, Epstein AE, Irimpen A, et al. Efficacy and safety of automatic remote monitoring for implantable eardioverter-defih- rillator follow-up.. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial [J].Circu|at~on, 2010,122 : 325.
-
6Crossley G, Boyle A, Vitense H,et al. The CONNECT(Clini- cal Evaluation of Remote Notification to Reduce Time to Clini- cal Decision) trial:the value of wireless remote monitoring with automatic clinician alerts [J]. J Am Coll Cardiol, 2011, 57: 1181.
-
7Spencker S,Cohan N,Koch L,et al. Potential role of home mo- nitoring to reduce inappropriate shocks in implantable cardio- verter-defibrillator patients due to lead failure [J]. Europace, 2009,11(4) : 483.
-
8Perinqs C,Bauer WR, Bondke HJ, at al. Remote monitoring of implantable -cardioverter defibrillators: results from the Relia- bility of IEGM Online Interpretation (RIONI) study[J]. Eu- ropace,2011,13(2) :221.
-
9Guedon-Moreau L, Lacroix D, Sadoul N, et al. for the ECOST trial Investigators: A randomized study of remote follow-up of implantable cardioverter defibrillators: Safety and efficacy re- port of the ECOST trial [J]. Eur Heart J,2013,34:605.
-
10Gu6don-Moreau L, Kouakam C, Klug D, et al. Decreased de- livery of inappropriate shocks achieved by remote monitoring of ICD: a substudy of the ECOST trial [J]. J Cardiovasc Electro- physiol,2014,25(7) :763.
二级参考文献25
-
1Kleemann T, Becker T, Doenges K, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter defibrillators over a period of > 10 years [ J ]. Circulation, 2007,115 ( 19 ) : 2 474.
-
2Neuzil P, Taborsky M, Holy F, et al. Early automatic remote detection of combined lead insulation defect and ICD damage [ J ]. Europace ,2008, 10( 5 ) :556.
-
3Spencker S, Coban N, Koch L, et al. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-de-fibrillator patients due to lead failure [ J ]. Europace, 2009,11 ( 4 ) : 409.
-
4Sweesy MW, Erickson SL, Crago JA, et al. Analysis of the effectiveness of in-office and transtelephonic follow-up in terms of pace- maker system complications[J]. Pacing Clin Electrophysiol,1994, 17(11 Pt 2) :2 001.
-
5Lazarus A. Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database [ J ]. Pacing Clin Electrophysiol, 2007, 30( Suppl 1 )S2.
-
6Nielsen J C, Kottkamp H, Zabel M, et al. Automatic home monitoring of implantable cardioverter defibrillators [J]. Europace, 2008, 10(6) : 729.
-
7Ellery S, Pakrashi T, Paul V, et al. Predicting mortality and rehospitalization in heart failure patients with home monitoring-the HomeCARE pilot study [ J ]. Clin Res Cardiol, 2006,95 ( Suppl 3 ) Ⅲ29.
-
8Perings C, Klein G, Toft E, et al. The RIONI study rationale and design: validation of the first stored electrograms transmitted via home monitoring in patients with implantable defibrillators [ J ]. Europace, 2006, 8(4) : 288.
-
9Ritter O, Bauer WR. Use of " IEGM Online" in ICD patients-early detection of inappropriate classified ventricular tachycardia via home monitoring[J]. Clin Res Cardiol, 2006, 95(7) : 368.
-
10Saxon LA, Boehmer JP, Neuman S, et al. Remote Active Monitoring in Patients with Heart Failure (RAPID-RF) : Design and rationale [ J ]. Journal of Cardiac Failure,2007,13 ( 4 ) : 241.
共引文献4
-
1张澍,林娜.重视注册研究,展现数据力量——美国NCDR ICD注册的启示[J].中华心律失常学杂志,2013,17(5):325-326. 被引量:3
-
2邓婷婷,申强,包忠武,蒋军军.起搏器植入术后规范化随访管理[J].临床医学工程,2015,22(3):375-376. 被引量:2
-
3曾治宇,林娜,张明东,张澍,吴明.注册研究在植入型心律转复除颤器研究领域的应用进展[J].中国循证医学杂志,2015,15(11):1362-1364.
-
4王凤梅,邢志博,宫志华.远程监测系统在植入电子器械装置患者中的应用进展[J].中国心脏起搏与心电生理杂志,2015,29(6):508-510. 被引量:1
-
1张华,庞智晖,周广全,何伟,陈鹏,陈镇秋,魏秋实.股骨头坏死随访图像处理系统的开发与应用[J].中国医药导报,2011,8(26):104-105.
-
2唐杨,唐学文.导管消融减少植入式心脏转复除颤器放电治疗的Meta分析[J].华西医学,2011,26(4):535-539.
-
3史东,段文涛,韩丽,张峰,任自文.心室电极脱位致心脏再同步化起搏除颤器误放电一例[J].中国心脏起搏与心电生理杂志,2014,28(5):463-464.
-
4费翔,张晨君,葛智儒.心脏再同步化治疗与室性心律失常关系研究进展[J].心血管病学进展,2014,35(6):669-672. 被引量:1
-
5林文华,邸成业.埋藏式心脏转复除颤器程控的参数不当致误放电的心腔内电图分析[J].中国心脏起搏与心电生理杂志,2012,26(4):360-363. 被引量:1
-
6张其同,刘彤.运动员植入ICD的临床管理[J].心电图杂志(电子版),2014,3(4):219-220.
-
7严激,陈康玉.心力衰竭非药物治疗:心脏再同步治疗和埋藏式心脏复律除颤器[J].中华心脏与心律电子杂志,2014,2(2):15-17. 被引量:1
-
8孙宝贵,张锋,刘少稳.植入性心脏电器械的远程监测系统[J].中国心脏起搏与心电生理杂志,2011,25(6):478-481. 被引量:3
-
9孙贤林,郭涛,韩明华,李淑敏,赵玲,刘中梅,杨西云,刘蓉.植入型心律转复除颤器35例次随访[J].中华心律失常学杂志,2005,9(4):287-290. 被引量:1
-
10于海波,梁延春,许国卿,刘荣,孙毅,王祖禄,韩雅玲.家庭监测型心脏转复除颤器术后管理的安全性及有效性[J].中国心脏起搏与心电生理杂志,2014,28(4):308-311. 被引量:2