期刊文献+

基于激光焊接纯钛可摘局部义齿支架的研究

Research on Laser Welding of Pure Titanium Removable Partial Denture
原文传递
导出
摘要 目的:运用光纤激光焊接技术,探索一组较优参数对断裂的纯钛可摘局部义齿支架进行激光焊接修复。方法:在制备的试件上,使用YLS-3000光纤激光器(最大功率为3 000 W)和KUKA机器人作为铸件加工的执行机构,采用手工编程或自动编程方式及轮廓控制方式进行精确的轨迹插补运动,调整激光功率、扫描速度、扫描次数,通过金相组织分析及组织纤维洛氏硬度分析得到较优工艺参数。基于此参数对断裂的纯钛义齿支架进行激光焊接修复。结果:成功完成了关于纯钛可摘局部义齿支架光纤激光焊接关键技术的研究,并获得符合临床要求的纯钛义齿支架。结论:在利用光纤激光器焊接修复断裂的铸造纯钛可摘局部义齿过程中,探索合适的工艺参数对焊接区形成良好的冶金结合和提高铸件的机械性能至关重要。 Objective:To explore a set of the optimal parameters of fracture of pure titanium removable partial denture for fiber laser welding repair.Methods:We choose specimen YLS-3000 fiber laser(the maximum power 3 000W)and KUKA robot as the processing eqaipment of the casting,manual programming and contour accurately track was used for interpolation motion control,adjust the laser power,scanning speed,scanning times.And metallographic structure analysis and organization fiber Rockwell hardness analysis was performed to get the optimal process parameters at the same time on the preparation of the specimen.Then repair the pure titanium denture support with laser welding technology based on the parameters.Results:The research on the key technology of fiber laser welding of pure titanium removable partial denture was successfully completed and the pure titanium denture frame was obtained which meets the clinical requirements.Conclusion:Exploring suitable process parameters in the process of repairing fracture of casting pure titanium removable partial denture using fiber laser welding technology is critical.
出处 《应用激光》 CSCD 北大核心 2016年第2期215-219,共5页 Applied Laser
基金 辽宁省自然科学基金资助项目(项目编号:2013022029) 辽宁省临床能力建设资助项目(项目编号:LNCCCD30-2015) 辽宁省百千万人才工程资助项目(项目编号:2013921023)
关键词 光纤激光焊接 纯钛 可摘局部义齿 工艺参数 fiber laser welding pure titanium removable partial denture the process parameters
  • 相关文献

参考文献4

二级参考文献42

  • 1徐萍.纯钛支架铸造缺陷原因分析[J].武警医学院学报,2007,16(3):299-300. 被引量:5
  • 2Takayama Y,Takishin N,Tsuchida F,et al.Survey on use of titanium dentures in Tsurumi University Dental Hospital for 11 years[J].J Prosthodont Res,2009,53(2):53-59.
  • 3Kononen M,Rintanen J,Waltimo A,et al.Titanium framework removable partial denture used for patient allergic to other metals:a clinical report and literature review[J].J Prosthet Dent,1995,73(1):4-7.
  • 4Rodrigues RC,Ribeiro RF,de Mattos Mda G,et al.Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures[J].J Prosthet Dent,2002,88 (3):290-296.
  • 5Kyung SJ,Suk JY,Yung SK.Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks[J].J Prosthet Dent,2001,86:93-98.
  • 6Vallittu PK,Kokkonen M.Deflection fatigue of cobalt-chromium,titanium,and gold alloy cast denture clasp[J].J Prothet Dent,1995,74(4):412-419.
  • 7Mabmoud AA,Wakabayashi N,Takahashi H.Prediction of permanent deformation in cast clasps for denture prostheses using a validated nonlinear finite element model[J].Dent Mater,2007,23(3):317-324.
  • 8Baltaga L,Watanabeb K,Miyakawab O.Internal porosity of cast titanium removable partial dentures:influence of sprue direction and diameter on porosity in simplified circumferential clasps[J].Dental Materials,2005,21 (6):530-537.
  • 9A1-Mesmar HS,Morgano SM,Mark LE.Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks[J].J Prosthet Dent,1999,82(1):15-21.
  • 10Baltag L,Watanabe K,Kusakari H,et al.Internal porosity of cast titanium removable partial dentures:Influence of sprue direction on porosity in circumferential clasps of a clinical framework design[J].J Prosthet Dent,2002,88(2):151-158.