期刊文献+

阵发性房颤对经肺热稀释法所监测参数的影响

Effect of Paroxysmal Atrial Fibrillation on Parameters Monitored by Transpulmonary Thermodilution Method
下载PDF
导出
摘要 目的探讨阵发性房颤对经肺热稀释法所监测参数准确性的影响。方法观察12例急诊EICU阵发性房颤患者在房颤前及房颤过程中所监测的血流动力学参数(心率、平均动脉压、心脏指数、系统血管阻力指数、胸腔内血容量指数、血管外肺水指数、肺部超声测定的B线数目)的变化。结果患者发生房颤时,心率较基线状态下明显上升[(123.3±20.0)次/min比(98.9±12.3)次/min,P=0.006];平均动脉压[(86.9±10.2)mm Hg(1 mm Hg=0.133 k Pa)比(93.0±12.5)mm Hg,P=0.058]、心脏指数[(2.82±0.62)L/(min·m2)比(3.31±1.02)L/(min·m2),P=0.058]及系统血管阻力指数[(2 254±947)dyn·s·cm-5·m2比(2 302±828)dyn·s·cm-5·m2,P=0.351]无变化;胸腔内血容量指数明显升高[(1 333±90)ml/m2比(937±111)ml/m2,P<0.001];血管外肺水指数明显升高[(16.1±1.1)ml/kg比(6.5±1.9)ml/kg,P<0.001];肺部超声测定的B线数目无变化(10.0±4.2比9.4±4.4,P=0.180)。结论发生房颤后经肺热稀释法会高估胸腔内血容量指数和血管外肺水指数,在临床工作中需要结合实际情况及其他监测手段如查体、肺超声检查等,进行综合判断及决策。 Objective To investigate the effect of atrial fibrillation on the accuracy of parameters monitored by transpulmonary thermodilution method. Methods Totally 12 patients from emergency intensive care unit with paroxysmal atrial fibrillation were enrolled. The hemodynamic parameters such as heart rate,mean arterial pressure,cardiac index,systemic vascular resistance index,intrathoracic blood volume index,and extravascular lung water index were monitored by transpulmonary thermodilution method before paroxysmal atrial fibrillation and during atrial fibrillation,the number of B-lines was detected by lung ultrasonography before and during paroxysmal atrial fibrillation. The changes of all the parameters were analyzed. Results When the paroxysmal atrial fibrillation happened,the heart rate increased significantly [( 123. 3 ± 20. 0) beat / min vs.( 98. 9 ± 12. 3)beat / min,P = 0. 006]; the mean arterial pressure [( 86. 9 ± 10. 2) mm Hg vs.( 93. 0 ± 12. 5) mm Hg,P =0. 058],cardiac index [( 2. 82 ± 0. 62) L /( min·m2) vs.( 3. 31 ± 1. 02) L/( min·m2),P = 0. 058]and systemic vascular resistance index [( 2 254 ± 947) dyn·s·cm- 5·m2vs.( 2 302 ± 828) dyn·s·cm- 5·m2,P = 0. 351] had no obvious change; however, the intrathoracic blood volume index significantly increased[( 1 333 ±90) ml /m2 vs.( 937 ± 111) ml / m2,P 〈0. 001]; extravascular lung water index also increased significantly [( 16. 1 ± 1. 1) ml / kg vs.( 6. 5 ± 1. 9) ml / kg,P〈 0. 001]. No significant difference was found in the number of B-lines detected by lung ultrasonography before and during atrial fibrillation( 10. 0 ± 4. 2 vs. 9. 4 ± 4. 4,P = 0. 180). Conclusion Both intrathoracic blood volume and extravascular lung water monitored by transpulmonary thermodilution method were overvalued during paroxysmal atrial fibrillation,which may mislead the clinical judgment and decision-making.
出处 《中国医学科学院学报》 CAS CSCD 北大核心 2016年第2期140-143,共4页 Acta Academiae Medicinae Sinicae
关键词 经肺热稀释技术 血管外肺水 胸腔内血容积 transpulmonary thermodilution method extravascular lung water intrathoracic blood volume
  • 相关文献

参考文献12

  • 1Mehta Y,Chauhan R,Ganguli S. Abrupt reduction of PEEP to float pulmonary artery catheter in difficult situations in ventilated patients[J]. J Cardiothorac Vasc Anesth,1994,8(4):485-486.
  • 2Lee ME,Matloff JM,Hackner E. Catheter-induced pulmonary artery hemorrhage[J]. J Thorac Cardiovasc Surg,1982,83(5):796-797.
  • 3Antonini M,Meloncelli S,Dantimi C,et al. The PiCCO system with brachial-axillary artery access in hemodynamic monitoring during surgery of abdominal aortic aneurysm[J]. Minerva Anestesiol,2001,67(6):447-456.
  • 4Baldi G,Gargani L,Abramo A,et al. Lung water assessment by lung ultrasonography in intensive care:a pilot study[J]. Intensive Care Med,2013,39(1):74-84.
  • 5Lichtenstein DA. Ultrasound examination of the lungs in the intensive care unit[J]. Pediatr Crit Care Med,2009,10(6):693-698.
  • 6Evgenov OV,Evgenov NV,Mollnes TE,et al. Methylene blue reduces pulmonary oedema and cyclo-oxygenase products in endotoxaemic sheep[J]. Eur Respir J,2002,20(4):957-964.
  • 7Sakka SG,Klein M,Reinhart K,et al. Prognostic value of extravascular lung water in critically ill patients[J]. Chest,2002,122(6):2080-2086.
  • 8Craig TR,Duffy MJ,Shyamsundar M,et al. Extravascular lung water indexed to predicted body weight is a novel predictor of intensive care unit mortality in patients with acute lung injury[J]. Crit Care Med,2010,38(1):114-120.
  • 9Kor DJ,Warner DO,Carter RE,et al. Extravascular lung water and pulmonary vascular permeability index as markers predictive of postoperative acute respiratory distress syndrome:a prospective cohort investigation[J]. Crit Care Med,2015,43(3):665-673.
  • 10沈菊芳,邱海波,杨毅,刘松桥,陈永铭,李家琼,吴彬,丁惠民.单指示剂法与重力法测定急性呼吸窘迫综合征犬血管外肺水的比较研究[J].中国危重病急救医学,2006,18(6):327-330. 被引量:17

二级参考文献16

  • 1刘大为.急性呼吸窘迫综合征的机械通气策略——由通气不均一向均一性的转变[J].中国危重病急救医学,2004,16(7):385-386. 被引量:38
  • 2Sakka S G,Klein M,Reinhart K,et al.Prognostic value of extravascular lung water in critically ill patients[J].Chest,2002,122:2080-2086.
  • 3Boussat S,Jacques J,Levy B,et al.Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema[J].Intensive Care Med,2002,28:712-718.
  • 4Halperin B D,Feeley T W,Mihm F G,et al.Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults[J].Chest,1985,88:649-652.
  • 5Malbouisson L M,Preteux F,Puybasset L,et al.Validation of a sotfware designed for computed tomographic (CT) measurement of lung water[J].Intensive Care Med,2001,27:602-608.
  • 6Ratzonelson R,Perel A,Berkenstadt H,et al.Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water[J].Crit Care Med,2004,32:1550-1554.
  • 7Roch A,Michelet P,Lambert D,et al.Accuracy of the double indicator method for measurement of extravascular lung water depends on the type of acute lung injury[J].Crit Care Med,2004,32:811-817.
  • 8Bernard G R,Artigas A,Bringham K L,et al.The American-European Consensus Conference on ARDS:definitions,mechanisms,relevant outcomes,and clinical trial coordination[J].Am J Respir Crit Care Med,1994,149:818-824.
  • 9Rossi P,Oldner A,Wanecek M,et al.Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia[J].Intensive Care Med,2003,29:460-466.
  • 10Ruiz-Bailen M,Fernandez-Mondejor E,Hurtado-Ruiz B,et al.Immediate application of positive-end expiratory pressure is more effective than delayed positive-end expiratory pressure to reduce extravascular lung water[J].Crit Care Med,1999,27:380-384.