期刊文献+

A RPC test station based on ROOT and VME

A RPC test station based on ROOT and VME
下载PDF
导出
摘要 Due to its advantages in large-area application situations, the R&D of the resistive plate chamber(RPC)has always been carried out. A performance test station for RPC R&D has been designed and developed based on the VME bus and ROOT in Linux. This system can be customized expediently according to the requirements of different tests, which facilitates detector R&D because of its automatic HV scan, especially for long-term test. With this system, we have implemented the RPC performance test,including the efficiency curve, counting rate, dark current and charge and timing resolution. Due to its advantages in large-area application situations, the R&D of the resistive plate chamber(RPC)has always been carried out. A performance test station for RPC R&D has been designed and developed based on the VME bus and ROOT in Linux. This system can be customized expediently according to the requirements of different tests, which facilitates detector R&D because of its automatic HV scan, especially for long-term test. With this system, we have implemented the RPC performance test,including the efficiency curve, counting rate, dark current and charge and timing resolution.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第2期79-85,共7页 核技术(英文)
基金 supported by the National Natural Science Foundation of China (No. 11305124) the Fundamental Research Funds for the Central Universities (No. xjj2013082)
关键词 VME总线 RPC 试验站 Linux 性能试验台 时间分辨率 长期试验 性能测试 Resistive plate chamber VME ROOT R&D Test station
  • 相关文献

参考文献5

二级参考文献20

  • 1[1]Santonico R. Nucl. Instr. and Meth., 1981, 187: 377
  • 2Santonico R. Nucl. Instr. and Meth., 1981, 187:377.
  • 3Root Users Guide 3.02C, October 2002.
  • 4Hohlmann M, Ford P, Gnanvo K. IEEE Trans Nucl Sci, 2009, 56: 1356-1363.
  • 5Borozdin K N, Hogan G E, Morris C. Nature, 2003, 422: 277-277.
  • 6Priedhorsky W C, Borozdin K N, Hogan G E. Rev Sci lnstrum, 2003, 74: 4294-4297.
  • 7Schultz L J, Borozdin K N, Gomez J J. Nucl lnstrum Meth Phys Res A, 2004, 519: 687-694.
  • 8Xie Y G, Chen Ch, Wang M. Particle detectors and data acquisition, Beijing (China): Science Press, 2003, 91-104.
  • 9Yang T, Zhao B, Zhang Ch. Nucl Electr Detect Technol, 2002, 5: 244-246.
  • 10TDC-GP2. 2-channel Universal Time-to-Digital Converter, version2.0, May, 2010.