针对SS4型电力机车92KM电磁接触器烧损粘连的故障进行原因分析并研究相应的整治措施,保证机车正常运行,最大限度减少机破等事故的发生。
For electromagnetic contactor type SS4 electric locomotive 92KM burning adhesion failure reasons are pointed out as well as the corresponding control measures which ensures the normal operation of the locomotive, and at last, machine accidents can be avoided.