Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges 被引量:1

Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges
下载PDF
导出
摘要 The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics~ chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post- discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone. The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics~ chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post- discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期469-472,共4页 等离子体科学和技术(英文版)
基金 performed using HPC resources from CALMIP(Grant 2011-[P1053]) supported by the French Agence Nationale de la Recherche under Project ANR-12-BS09-0019-1 through REMOVAL
关键词 DC corona discharge humid air chemistry plasma simulation NO treatment DC corona discharge, humid air chemistry, plasma simulation, NO treatment
  • 相关文献

参考文献12

  • 1Kossyi I A, Yu Kostinsky A, Matveyev A A, et al. 1992, Plasma Sources Sci. Technol., 1: 207.
  • 2Orlandini I, Riedel U. 2000, J. Phys. D: Appl. Phys., 33: 2467.
  • 3Gentile A C, Kushner M J. 1996, J. Appl. Phys., 79: 3877.
  • 4Eichwald O, Yousfi M, Hennad A, et al. 1997, J. Appl. Phys., 82: 4781.
  • 5Eichwald O, Guntoro N A, Yousfi M, et al. 2002, J. Phys. D: Appl. Phys., 35: 439.
  • 6Dorai R, Kushner M J. 2003, J. Phys. D: Appl. Phys., 36: 1075.
  • 7Marode E, Djermoune D, Dessante P, et al. 2009, Plasma Phys. Control. Fusion, 51: 124002.
  • 8Meziane M, Eichwald O, Sarrette J P, et al. 2013, J. Appl. Phys., 113: 153302.
  • 9Eichwald O, Ducasse O, Dubois D, et al. 2008, J. Phys. D: Appl. Phys., 41: 234002.
  • 10https://www.calmip.univ-toulouse.fr/spip/spip.php7r ubrique93 For more information about the High Performance Computer “EOS” used for calculation presented in this paper.