摘要 When subjected to high voltages between opened contacts, vacuum interrupters may emit X-rays. In order to ensure that these are of an acceptable level, vacuum interrupters should comply with the limits for X-ray emission and the test procedures to be carried out to verify this based on relevant standards and specifications. In this paper, a comprehensive experimental study has been performed for 126 kV vacuum interrupters used in a transmission system to understand the X-radiation level and its influence by three main parameters, namely applied power-frequency voltage, contact gap and power=frequency voltage conditioning. The radiation instrument is an FJ347 radiometer and the X-radiation dose was measured at the power-frequency test voltage. These tests demonstrated that the X-radiation emission level for a 126 kV vacuum interrupter did not exceed the following: 5 μSv per hour at a rated voltage of 126 kV and 150 μSv per hour at a power-frequency voltage of 230 kV at 1 m distance. The X-radiation dose increased with the applied power-frequency voltage increasing and decreased with the contact gap increasing. The X- radiation dose for 126 kV vacuum interrupters decreased by 57% after the conditioning procedure with a certain power-frequency voltage. During the conditioning procedure, the average value of the X-radiation dose was 4.49 mSv, which means if a professional conditions 180 interrupters per year, it will be safe at the 6.4 m distance. When subjected to high voltages between opened contacts, vacuum interrupters may emit X-rays. In order to ensure that these are of an acceptable level, vacuum interrupters should comply with the limits for X-ray emission and the test procedures to be carried out to verify this based on relevant standards and specifications. In this paper, a comprehensive experimental study has been performed for 126 kV vacuum interrupters used in a transmission system to understand the X-radiation level and its influence by three main parameters, namely applied power-frequency voltage, contact gap and power=frequency voltage conditioning. The radiation instrument is an FJ347 radiometer and the X-radiation dose was measured at the power-frequency test voltage. These tests demonstrated that the X-radiation emission level for a 126 kV vacuum interrupter did not exceed the following: 5 μSv per hour at a rated voltage of 126 kV and 150 μSv per hour at a power-frequency voltage of 230 kV at 1 m distance. The X-radiation dose increased with the applied power-frequency voltage increasing and decreased with the contact gap increasing. The X- radiation dose for 126 kV vacuum interrupters decreased by 57% after the conditioning procedure with a certain power-frequency voltage. During the conditioning procedure, the average value of the X-radiation dose was 4.49 mSv, which means if a professional conditions 180 interrupters per year, it will be safe at the 6.4 m distance.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期577-582,共6页 等离子体科学和技术(英文版)
基金 supported by National Key Basic Research Program of China(973 Program)(No.2015CB251002)
关键词 vacuum interrupter X-radiation power-frequency voltage contact gap volt-age conditioning vacuum interrupter, X-radiation, power-frequency voltage, contact gap, volt-age conditioning
  • 相关文献

参考文献14

  • 1Garzon R D. 2002, High Voltage Circuit Breaker Design and Applications (2nd Edition), Marcel Dekker Inc., New York.
  • 2Greenwood A. 1994, Vacuum Switchgear. The Institution of Electrical Engineers, London.
  • 3Matsui Y, Nagatake K, Takeshita M, et al. 2006, Development and technology of high voltage VCBs: Brief history and state of art. XXIInd International Symposium on Discharges and Electrical Insulation in Vacuum, Matsue, Japan.
  • 4Homma M, Sakaki M, Kaneko E, et al. 2006, IEEE Trans. Dielectrics and Electrical Insulation, 13: 85.
  • 5Wang J, Wang J. 2000, Review of theoretical research in vacuum arc and their applications in China. XlXth International Symposium on Discharges and Electrical Insulation in Vacuum, Xi’an, China.
  • 6Liu Z, Wang J, Xiu S, et al. 2007, IEEE Trans. Plasma Sci., 35: 856.
  • 7Slade P G. 2007, The Vacuum Interrupter: Theory, Design, and Application. CRC Press Taylor & Francis Group, Boca Raton.
  • 8IEC 62271-1. 2007, High-Voltage Switchgear and Controlgear-partl: Common Specifications. IEC Publication.
  • 9ANSI C37.85. 1989, Alternating-current high-voltage power vacuum interrupters-safety requirements for X-radiation limits. American National Standard.
  • 10Renz R, Gentsch D. 2010, Permissible X-ray radiation emitted by vacuum interrupters/devices at rated operating conditions. XXIVth International Symposium on Discharges and Electrical Insulation in Vacuum, Braunschweig, Germany.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部