期刊文献+

铂电阻温度计自动标定系统设计 被引量:3

Design of the Automatic Calibration System for Platinum Resistance Thermometer
下载PDF
导出
摘要 针对传统铂电阻温度计标定方法工作量大、效率低的问题,设计了一套基于计算机的自动标定系统。系统采用VB6.0作为软件开发平台,编程实现计算机对温度源、标准温度计的自动控制、数据采集及存储,同时调用Excel进行温度计标定数据的自动拟合。根据标定设备的硬件配置,计算得到系统的不确定度小于0.02℃。实验结果表明,在-40~150℃的标定温度范围内,标定后的温度计测量误差小于±0.03℃。 Aiming at the problems of large amount of labor and low efficiency in the traditional calibration method of platinum resistance thermometer,an automatic calibration system is designed based on computer. The system adopts VB6.0 as the software development platform,the automatic control, data acquisition and storage of temperature source and standard thermometer are realized by programming in computer ; and the calibration data of thermometer are automatically fitted by calling Excel. Depending on the hardware configuration of calibration device, the uncertainty of the system is less than 0.02℃, and the experimental results indicate that the measurement error of the calibrated thermometer is less than ±0.03℃ within in the calibration temperature range of -40 - 150℃.
出处 《自动化仪表》 CAS 2016年第5期71-74,共4页 Process Automation Instrumentation
基金 浙江省科技计划基金资助项目(编号:2014C33114) 国家质检总局科技计划基金资助项目(编号:2014IK075)
关键词 铂电阻温度计 色谱仪 传感器 信号调理电路 A/D转换器 自动标定 VB6.0 不确定度 Platinum resistance thermometer Chromatograph Sensor Signal conditioning circuit A/D converter Automatic calibration VB6.0 Uncertainty