期刊文献+

评价双层安全壳直接旁路泄漏的设计思路研究 被引量:1

Design approach of dual containment direct bypass leakage evaluation
下载PDF
导出
摘要 本文探讨了评价压水堆全压双层安全壳直接旁路泄漏的设计思路,特别是如何识别潜在旁路泄漏途径和如何确定旁路泄漏率,提出环廊初始维持较大负压使事故后不出现"正压"阶段从而不需评价"正压"期间旁路泄漏,和环廊初始维持较小负压且需评价事故后"正压"阶段持续时间两种主要设计思路,可指导研发先进压水堆核电厂时选择系统设计方案。 Two design approaches of dual containment direct bypass leakage evaluation (especially the identification of potential bypass leakage paths and the determination of bypass leakage rate) are proposed, maintaining a big initial annulus negative pressure and eliminating the positive pressure period after accidents which allows no direct bypass leakage during the positive pressure period, or maintaining a small initial annulus negative pressure and evaluating the positive pressure period after accidents, which can guide the advanced nuclear power plant research and development.
作者 魏淑虹 郑华
出处 《核科学与工程》 CAS CSCD 北大核心 2016年第1期56-61,共6页 Nuclear Science and Engineering
关键词 双层安全壳 直接旁路泄漏 环廊通风系统 dual containment direct bypass leakage Annulus ventilation system
  • 相关文献

参考文献4

  • 1U.S. NRC. NURECr0800 Standard review plan branch technical position 6-3 Determination of bypass leakage paths in dual containment plants[R]. March 2007.
  • 2U.S. NRC. NUREG-0800 Standard review plan Section 6.2.3 Secondary containment functional design [R]. March 2007.
  • 3U.S. NRC. NUREG-0800 Standard review plan branch technical position 6-2 Minimum containment pressure model for PWR ECCS performance evaluation [ R]. March 2007.
  • 4AREVA NP Inc. US EPR Final safety analysis report [R]. May 3, 2013.