期刊文献+

Pd-C高温共晶点复现技术研究

Study on Recurrence Technology for Pd-C High Temperature Eutectic Point
下载PDF
导出
摘要 设计了Pd-C高温共晶点复现装置,包括复现用高温均热炉炉体、温度控制系统、真空泵、充气保护装置、水冷系统、复现用的石墨坩埚、二等B型标准热电偶和Pt-Pd热电偶等。在此基础上进行了石墨坩埚的灌注和共晶点复现,并对复现的试验数据进行了相应的分析。结果表明本装置温度复现性可以达到0.2℃以下。 This paper designs a set for recurrence of the Pd-C high temperature eutectic point,which consists of a high temperature furnace,a temperature-controlling system,a pump,a gas protection system,a water-cooling system,a graphite crucible,a 2-class standard B-type thermocouple and a Pt / Pd thermocouple. The procedure of filling the crucible and reproducing the eutectic point are presented,and the experimental data are analyzed according to the recurrence results. It showed the reproducibility of temperature was less than 0. 2℃.
出处 《计测技术》 2016年第2期19-22,共4页 Metrology & Measurement Technology
基金 国家"十二五"技术基础科研项目(JSJC2012205A003)
关键词 Pd-C 共晶点 温坪 高温固定点 热电偶校准 高温均热炉 Pd-C eutectic point temperature platform high temperature fixed point thermocouple calibration high temperature furnace
  • 相关文献

参考文献8

  • 1Yamad Y, Sasajima N, Sakuma F, et al. Realizing fixed point the copper point up to 2500℃ using metal-carbon eutectics [C] //Proceeding of TEMPECKO. 2001 : 19 -26.
  • 2Yamada Y, Duan Y, Ballico M, et al. Measurement of Rh-C, Pt-C and Ru-C euteetic points by four national metrology insti- tutes[J]. Metrologia, 2001, 38:203-211.
  • 3Machin G, Yamada Y, Lowe D. A comparison of high tempera- ture fixed-points of Pt-C and Re-C constructed by BIPM, NMIJ and NPL[J]. TEMPMEKO, 2004, 1049-1055.
  • 4Yamada Y, Sakate H, Sakuma F, et al. High-temperature fixed points in the range 1150℃ to 2500℃ using metal-carbon eutectics[J]. Metrologia, 2001.
  • 5王铁军,柏成玉,原遵东,董伟,王景辉,段宇宁.高温共晶固定点的建立与复现[J].计量学报,2007,28(z1):23-27. 被引量:5
  • 6Yamada Y. Metal-carbon eutectic high-temperature standards [J]. SICE, 2003, 918-921.
  • 7郑玮,向明东,俞登峰.熔丝法在钯点分度热电偶的研究[J].计量学报,2010(5):440-444. 被引量:1
  • 8Anhalt K, Hartmann J, I_owe D, et al. A comparison of Co-C, Pd- C, Pt-C, Ru-C and Re-C eutectic fixed points independently manu- factured by three different institutes [C]//Proc. Newrad. Davos, Switzerland: PMOD/WRC, 2005: 289-290.

二级参考文献11

  • 1俞登峰,郑玮.熔丝法测定钯点计算方法的改进研究[J].现代测量与实验室管理,2008,16(1):13-15. 被引量:1
  • 2[1]Preston-Thomas H.The International Temperature Scale of 1990(ITS-90)[J].Metrologia,1990,27:3~10.
  • 3[2]Comite Consuhatif de Thermom trie(CCT).Rapport de la 19e session(septembre 1996)[R].Sevres:Bureau International des Poids et Mesures,1998.
  • 4[3]Yamada Y,Sakate H,Sakuma F,Ono A.Radiometric observation of melting and freezing plateaus for a series of metal-carbon eutectic points in the rarrge 1 330 ℃ to 1 950 ℃[J].Metrologia,1999,36:207~209.
  • 5[4]Machin G,Beynon G,Edler F,Fourrez S et al.HIMERT:A Pan-European Project for the Development of Metal-Carbon Eutectics as Temperature Standards[A].Temperature:Its Measurement and Control in Science and Industry,7(Ripple et al.ed.),AIP Conference Proceedings[C],Melville,New York:2003,285~290.
  • 6[5]Sadli M,Bourson F,Fanjeaux M,Bonnier G.Study of Metal -Carbon Eutectic Points:From Construction To Temperature Determination[A].Proc.TEMPMEKO[C],2004
  • 7[6]Machin G,Gibson C E,Lowe D,et al.A comparison of ITS-90 and detector-based Scales between NPL and NIST using metal-carbon eutectics[A].Proc.TEMPMEKO[C],2004.
  • 8[7]Sadli M,Fischer J,Yamada Y,et al.Review of MetalCarbon Eutectic Temperatures:Proposal for New ITS-90 Secondary Points[A].Proc.TEMPMEKO[C],2004.
  • 9[8]Yamada Y,Khlemoy B,Wang Y,Wang T,Anhalt K.Application of Metal(Carbide)-Carbon Eutectic Fixed Points in Radiometry[J].Metrologia,2006,43(2):140~144.
  • 10[9]王铁军,等.高温固定点扩展[R].北京:中国计量科学研究院,2006.