摘要
以广东某医院废水处理工程为例,介绍"水解酸化+生物接触氧化+消毒"工艺处理该医院废水的设计参数、处理效果及运行成本。运行结果表明:该工艺可行,运行费用低,运行效果稳定,处理后的废水达到了《医疗机构水污染物排放标准》(GB18466-2005)中综合医疗机构和其他医疗机构水污染物排放限值的要求。
Taking a hospital wastewater treatment engineering in Guangdong province as the example, design parameters, treatment effect and operation cost of treating hospital wastewater by hydrolysis and acidogenesis+biological contact oxidation+disinfect process were introduced. The result showed that this process was feasible, with low operation cost and stable operation. The treated wastewater could meet the requirements of comprehensive medical institutions and other medical institutions of water pollutant discharge limits of the discharge standard of water pollutants for medical organization(GB18466-2005).