期刊文献+

一种新型的平面叉指电极传感器的设计与实现 被引量:6

Design and Realization of A Novel Planar Interdigitated Electrode Sensor
下载PDF
导出
摘要 随着我国水质标准的日趋严格,无机盐类尤其是硝酸盐作为水体污染的重要标志,越来越被研究学者关注。本文提出了一种用于无机物离子检测的新型单片式平面叉指电极传感器,基于交流阻抗技术和电极动力学分析了电极/溶液体系,量化了电极与溶液界面上的双电层效应和传质过程,并建立等效电路模型,深入探讨了在不同频率段下电极/溶液体系的阻抗特性和相位特性。根据不同浓度的无机盐溶液和不同种类的无机盐溶液的实验结果表明,平面叉指电极传感器具有较好的鉴别能力。 With increasingly stringent environmental standards, inorganic salts, especially nitrate as an important symbol of water pollution, have been highly focused by researchers. This paper proposed a new type of planar interdigitated electrode sensor for inorganic ions detection and centered around mechanism of it in electrolyte solution with AC impedance technique and electrode kinetics analysis. An equivalent circuit model for double layer effect and electrode process were proposed and applied to characterize the responses of impedance and phase over the different frequency ranges. Meanwhile, experimental results show that planar interdigitated electrode sensor have the ability to distinguish the different concentrations of inorganic salt solution, and the distinct identification of nitrate and phosphate based on the features of impedance spectroscopy and phase spectroscopy was also presented in this work.
出处 《传感技术学报》 CAS CSCD 北大核心 2016年第3期356-361,共6页 Chinese Journal of Sensors and Actuators
基金 江西省对外合作项目(20141BDH80001)
关键词 传感器 无机物离子检测 交流阻抗技术 等效电路模型 双电层效应 sensors inorganic salts detection AC impedance technique equivalent circuit model double layer effect
  • 相关文献

参考文献13

  • 1黎洪松,刘俊.水质检测传感器研究的新进展[J].传感器与微系统,2012,31(3):11-14. 被引量:23
  • 2喻嵘,王玉皞,王艳庆,王晓磊,周军乐.用于水质硝酸盐浓度在线检测的电磁传感器设计[J].传感技术学报,2013,26(6):774-778. 被引量:3
  • 3Mutlu Sahin, Yucel Sahin, Adnan Ozean. Ionchromatography Po- tentiometric Detection of Inorganic Anions and Cations Using Polypyrrole and Overoxidized Polypyrrole Electrode [J].Sensors and Actuators B, 2008,133 : 5-14.
  • 4Dimosthenis L.Giokas, Athanasios G. Vlessidis. Synthetic Mem- branes (Vesicles) in Inorganieion Analysis : A review [ J ]. Analyti- ca Chimica Aeta,2011,683:156-169.
  • 5李雅卓,王广伟,金建余,王晓萍.基于两电极体系脉冲计时电流法的离子选择性检测[J].传感技术学报,2014,27(1):12-16. 被引量:4
  • 6Wang Shurong, Kang Yanfei, Wang Liwei, et al. Organic/Inorgan- ic Hybrid Sensors: A Review [ J]. Sensors and Actuators B, 2013, 182 : 467-481.
  • 7Almudena Rivadeneyra, Jose Feruandez- Salmeran, Manuel Agu- do, et al. Design and Characterization of A Low Thermal Drift Ca- pacitive Humidity Sensor by Inkjet-Printing[J]. Sensors and Actu- ators B, 2014,195 : 123-131.
  • 8Steffen O P Blume, Ridha Ben-Mrad, Pierre E. Sullivan. Modelling the Capacitance of Muhilayer Conductor-facing Interdigitated Elec- trode Structures [ J].Sensors and Actuators B, 2015,213 : 423-433.
  • 9Vadim F.Lvovich. Impedance Spectroscopy: Applications to Elec- trochemical and DielectricPhenomena [M]. John Wiley & Sons Inc,2012:59-85.
  • 10Wang Xiaolei, Wang Yuhao, Leung Henry. Mechanism and Exper- iment of Planar Electrode Sensors in Water Pollution Measurement [J]. IEEE Transactions on Instrumentation and Measurement, 2015,64(2) :516-523.

二级参考文献57

  • 1甘琦,周昕,赵斌元,胡克鳌.成型活性炭的制备研究进展[J].材料导报,2006,20(1):61-63. 被引量:44
  • 2胡卫军,邹绍芳,Alisa Rudnitskaya,王平.汞离子选择电极在海水痕量元素检测中的应用[J].传感技术学报,2007,20(6):1215-1218. 被引量:2
  • 3姚守拙 谭胜连 等.金膜压电石英晶体液振传感元件-电解富集法测定废水中微量汞[J].分析实验室,1988,7(4):1-1.
  • 4World Health Organization.Guidelines for drinking-water quality(3rd ed)[DB/OL].[2011—05—01].http:∥www.who.int/water_sanitation_health/dwq/gdwq3rev/en/.
  • 5EU Council.Council directive 98/83/EC on the quality of water in-tented for human consumption[DB/OL].[2011—05—01] http:∥www.lenntech.com/applications/drinking/standards/eu-s-drin-king-water-standards.htm.
  • 6US EPA.National primary drinking water regulations[DB/OL].[2011—05—01].http:∥water.epa.gov/drink/contaminants/in-dex.cfm.
  • 7Chen D Y,Chan P K.An intelligent ISFET sensory system withtemperature and drift compensation for long-term monitoring[J].IEEE Sensors Journal,2008,8(12):1948-1959.
  • 8Barnard A H,Barnard A H,Rhoades B,et al.Real-time and long-term monitoring of phosphate using the in-situ cycle sensor[R].Oceans 2009,MTS/IEEE Biloxi-marine technology for our future:Global and local challenges,Biloxi,2009.
  • 9Zhuiykov S.Development of ceramic electrochemical sensor basedon Bi2 Ru2 O7+x RuO2 sub-micron oxide sensing electrode forwater quality monitoring[J].Ceramics International,2010,136:2407-2413.
  • 10Zhuiykov S,Kats E,Marney D,et al.Improved antifouling resis-tance of electrochemical water quality sensors based on Cu2O-doped RuO2 sensing electrode[J].Progress in Organic Coatings,2011,70:67-73.

共引文献27

同被引文献35

引证文献6

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部