非球面人工晶状体度数计算的最优化 被引量:1

Preliminary evaluation of an algorithm to minimize the power error selection of an aspheric intraocular lens by optimizing the estimation of the corneal power and the effective lens position
下载PDF
导出
摘要 目的:通过评价非球面人工晶状体(intraocular lens,IOL)屈光度的可预测性,初步开发一种计算屈光度(PIOL)的优化算法。方法:本研究纳入植入非球面IOL(LENTIS L-313,Oculentis Gmb H)65眼,并分为2组:A组8例12眼,PIOL≥23.0D;B组35例53眼,PIOL〈23.0D。术后3mo进行屈光度可预测性评价。参考角膜屈光力估计所致的可变性屈光指数计算出校正的IOL度数(PIOLadj)及屈光结果,根据年龄和解剖学因素得出校正的有效晶状体位置(adjusted effective lens position,ELPadj)。结果:术后A、B两组等效球镜度数分别为-0.75~+0.75D、-1.38~+0.75D。A、B两组的PIOLadj和实际晶状体屈光度(PIOLReal)之间无统计学差异(P=0.64、0.82)。BlandAltman分析显示A、B两组PIOLadj和PIOLReal之间的一致性区间分别为+1.11^-0.96D和+1.14^-1.18D。Hoffer Q公式和Holladay I公式计算PIOLadj和PIOL之间存在临床和统计学上的显著差异(P〈0.01)。结论:植入非球面IOL白内障手术的屈光可预测性可通过平行轴光学联合线性法则使角膜屈光力及晶状体位置相关误差最小化。 AIM : To evaluate the refractive predictability achieved with an aspheric intraocular lens( IOL) and to develop a preliminary optimized algorithmfor the calculation of its power( PIOL).METHODS: This study included 65 eyes implanted with the aspheric IOLLENTIS L-313( Oculentis Gmb H) that were divided into 2 groups: 12 eyes( 8 patients) with PIOL≥23. 0 D( group A),and 53 eyes( 35 patients) with PIOL23. 0 D( group B). The refractive predictability was evaluated at 3mo postoperatively. An adjusted IOL power( PIOLadj) was calculated considering a variable refractive index for corneal power estimation, the refractive outcome obtained,and an adjusted effective lens position( ELPadj) according to age and anatomical factors. RESULTS: Postoperative spherical equivalent ranged from-0. 75 to + 0. 75 D and from-1. 38 to + 0. 75 D in groups A and B,respectively. No statistically significant differences were found in groups A( P = 0. 64) and B( P =0. 82) between PIOLadjand the IOL power implanted( PIOLReal). The Bland and Altman analysis showed ranges of agreement between PIOLadjand PIOLReal of +1. 11 to-0. 96 D and +1. 14 to-1. 18 D in groups A and B,respectively.Clinically and statistically significant differences were found between PIOLadjand PIOLobtained with Hoffer Q and Holladay I formulas( P0. 01).CONCLUSION: The refractive predictability of cataract surgery with implantation of an aspheric IOL can be optimized using paraxial optics combined with linear algorithms to minimize the error associated to the estimation of corneal power and ELP.
出处 《国际眼科杂志》 CAS 2016年第6期1001-1008,共8页 International Eye Science
关键词 非球面人工晶状体 人工晶状体屈光度计算 有效晶状体位置 aspheric intraocular lens intraocular lens power calculation effective lens position
  • 相关文献

参考文献30

  • 1Alió JL, Schimchak P, Negri HP, Montés-Micó R. Crystalline lens optical dysfunction through aging. Ophthalmology 2005; 112(11):2022-2029.
  • 2Philip K, Martinez A, Ho A, Conrad F, Ale J, Mitchell P, Sankaridurg P. Total ocular, anterior corneal and lenticular higher order aberrations in hyperopic, myopic and emmetropic eyes. Vision Res 2012; 52(1):31-37.
  • 3Lyall DA, Srinivasan S, Gray LS. Changes in ocular monochromatic higher-order aberrations in the aging eye. Optom Vis Sci 2013; 90(9):996-1003.
  • 4Fujikado T, Kuroda T, Ninomiya S, Maeda N, Tano Y, Oshika T, Hirohara Y, Mihashi T. Age-related changes in ocular and corneal aberrations. Am J Ophthalmol 2004; 138(1):143-146.
  • 5Amano S, Amano Y, Yamagami S, Miyai T, Miyata K, Samejima T, Oshika T. Age-related changes in corneal and ocular higher-order wavefront aberrations. Am J Ophthalmol 2004; 137(6):988-992.
  • 6Glasser A, Campbell MC. Presbyopia and the optical changes in the human crystalline lens with age. Vision Res 1998; 38(2):209-229.
  • 7Schuster AK, Tesarz J, Vossmerbaeumer U. The impact on vision of aspheric to spherical monofocal intraocular lenses in cataract surgery: a systematic review with meta-analysis. Ophthalmology 2013; 120(11):2166-2175.
  • 8Langenbucher A, Janunts E, Seitz B, Kannengieβer M, Eppig T. Theoretical image performance with customized aspheric and spherical IOLs - when do we get a benefit from customized aspheric design? Z Med Phys 2014; 24(2):94-103.
  • 9Guo H, Goncharov A, Dainty C. Intraocular lens implantation position sensitivity as a function of refractive error. Ophthalmic Physiol Opt 2012; 32(2):117-124.
  • 10Dick HB. Recent developments in aspheric intraocular lenses. Curr Opin Ophthalmol 2009; 20(1):25-32.

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部