研究使用傅立叶红外光谱(ATR)法对PP和PC两种材质的塑料奶瓶快速鉴别的方法。利用ATR法对送检的两件塑料奶瓶样品进行鉴别。结果表明,ATR法具有分析时间短、样品需求量小,几乎不破坏样品,不消耗检材,快速简便,分析结果满意等优点。
The rapid identification method of PP and PC plastic feeding bottles was studied. The submitted sample of two plastic feeding bottles have been identified by Fourier transform infrared spectroscopy(ATR, Attenuated total refraction). The results indicate that this method(ATR) has advantages such as short analysis time, demand for small samples, almost without damage of samples not expendable samples, rapid, simple, and satisfactory results, etc.
出处
《食品工业》
CAS
北大核心
2016年第5期276-278,共3页
The Food Industry