期刊文献+

An efficient calibration method for SQUID measurement system using three orthogonal Helmholtz coils 被引量:1

An efficient calibration method for SQUID measurement system using three orthogonal Helmholtz coils
下载PDF
导出
摘要 For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately. For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期585-588,共4页 中国物理B(英文版)
基金 Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200) the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
关键词 SQUID MAGNETOMETER Tesla/volt coefficient calibration three-dimensional Helmholtz coil SQUID magnetometer Tesla/volt coefficient calibration three-dimensional Helmholtz coil
  • 相关文献

参考文献13

  • 1Andr? W and Nowak H 2007 Magnetism in Medicine: A Handbook, 2nd edn. (Berlin: WILEY-VCH Verlag Berlin GmbH) pp. 101-152.
  • 2Qiu Y, Li H, Zhang S L, Wang Y L, Kong X Y, Zhang C X, Zhang Y S, Xu X F, Yang K and Xie X M 2015 Chin. Phys. B 24 078501.
  • 3Melo C F D, Araújo R L, Ardjomand L M, Quoirin N S R, Ikeda M and Costa A A 2009 Measurement 42 1330.
  • 4Tao W, Gao J, Wei Y K, Liu Z H, Zhang C, Zhang Y, Wang H and Ma P 2012 10th International Symposium on Antennas, Propagation and EM Theory (ISAPE), IEEE, October 22-26, 2012, Xian, China, p. 277.
  • 5Zhang Y S, Qiu Y, Zhang C X, Li H, Zhang S L, Wang Y L, Xu X F, Ding H S and Kong X Y 2014 Acta Phys. Sin. 63 228501 (in Chinese).
  • 6Adachi Y, Higuchi M, Oyama D, Haruta Y, Kawabata S and Uehara G 2014 IEEE Trans. Mag. 50 5001304.
  • 7Vivaldi V, Sorrentino A, Sommariva S, Piana M, Rombetto S and Russo M 2014 Biomag 2014, August 24-28, 2014, Halifax, Canada.
  • 8Pasquarelli A, Melis M, Marzetti L, Muller H P and Erné S N 2004 Neurol. Clin. Neurophysiol 2004:94, PMID: 16012682.
  • 9Bruno A C and Costa Ribeiro P 1991 Rev. Sci. Instrum. 62 1005.
  • 10Chella F, Zappasodi F, Marzetti L, Della Penna S and Pizzella V 2012 Phys. Med. Biol. 57 4855.

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部