A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods 被引量:3

A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods
下载PDF
导出
摘要 The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoretical methods such as FLUKA,GEANT4 Monte Carlo(MC) methods and XCOM program in this work.Calculated coefficients were also compared with the National Institute of Standards and Technology(NIST) values.Obtained results were highly in accordance with each other and NIST values.Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons(60,80,and 150 keV) when compared with the NIST values. The gamma-ray mass attenuation coefficients of blood,bone,lung,eye lens,adipose,tissue,muscle,brain and skin were calculated at different energies(60,80,150,400,500,600,1000,1250,1500,and 2000 keV) by various theoretical methods such as FLUKA,GEANT4 Monte Carlo(MC) methods and XCOM program in this work.Calculated coefficients were also compared with the National Institute of Standards and Technology(NIST) values.Obtained results were highly in accordance with each other and NIST values.Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons(60,80,and 150 keV) when compared with the NIST values.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期31-39,共9页 核技术(英文)
基金 supported by Scientific Research 277 Project of Ege University under Project No.2014 FEN 026 278 Uludag University under Project No.OUAP(F)-2012/26
关键词 质量衰减系数 蒙特卡洛方法 GEANT4 部位 NIST 美国国家标准 能量计算 眼晶状体 Gamma-ray mass attenuation coefficient FLUKA GEANT4 XCOM
  • 相关文献

参考文献27

  • 1J.T. Bushberg, J.A. Seibert, E.M. Leidholdt, J.M. Boone, TheEssential Physics of Medical Imaging (William-Wilkins Press,New York, 2001).
  • 2M.J. Berger, J.H. Hubbell, Photon Cross section on a PersonalComputer (XCOM). NBSIR87-3597 (National Institute of Standardsand Technology, Gaithersburg, 1987).
  • 3T.T. Bohlen, F. Cerutti, M.P.W. Chin et al., The FLUKA code:developments and challenges for high energy and medicalapplications. Nucl. Data Sheets 120, 211–214 (2014). doi:10.1016/j.nds.2014.07.049.
  • 4A. Ferrari, P.R. Sala, A. Fasso, et al., Fluka: A Multi-ParticleTransport Code. CERN, INFN/TC_05/11, SLAC-R-773 (2005).
  • 5S. Agostinelli, J. Allison, K. Amako et al., Geant4-a simulationtoolkit. Nucl. Instrum. Methods A 506, 250–303 (2003). doi:10.1016/S0168-9002(03)01368-8.
  • 6J. Allison, K. Amako, J. Apostolakis et al., Geant4 developmentsand applications. IEEE Trans. Nucl. Sci. 53, 270–278 (2006).doi:10.1109/TNS.2006.869826.
  • 7E.E. Ermis, C. Celiktas, E. Pilicer, A method to enhance coincidencetime resolution with applications for medical imagingsystems (TOF/PET). Radiat. Meas. 62, 52–59 (2014). doi:10.1016/j.radmeas.2014.01.013.
  • 8B. Alpat, E. Pilicer, S. Blasko et al., Total and partial fragmentationcross-section of 500 MeV/nucleon carbon ions on differenttarget materials. IEEE Trans. Nucl. Sci. 60, 4673–4682 (2013).doi:10.1109/TNS.2013.2284855.
  • 9I. Tapan, F.B. Pilicer, Silicon tracker simulation for the TurkishAccelerator Center particle factory. Nucl. Instrum. Methods A765, 240–243 (2014). doi:10.1016/j.nima.2014.05.100.
  • 10B. Alpat, E. Pilicer, L. Servoli et al., Full Geant4 and FLUKAsimulations of an e-LINAC for its use in particle detectors performancetests. JINST 7, P03013 (2012). doi:10.1088/1748-0221/7/03/P03013.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部