一起室内游泳馆氯气刺激反应事件的调查 被引量:2

An Event of Stimulus-response for Acute Chlorine Gas Release in Indoor Swimming Pool
下载PDF
导出
摘要 目的调查某室内游泳馆发生一起多人急性氯气刺激反应事件的原因,避免今后类似事件的发生。方法采用流行病学调查方法对室内游泳馆的设备设施和刺激反应患者进行调查。依据《公共场所卫生检验方法第1部分:物理因素》(GB/T 18204.1-2013)、《公共场所卫生检验方法第2部分:化学污染物》(GB/T18204.2-2014)对游泳馆内空气质量进行检测,依据《生活饮用水标准检验方法》(GB/T 5750-2006)、《游泳池水微生物检验方法细菌总数测定》(GB/T 18204.9-2000)、《游泳池水微生物检验方法大肠菌群测定》(GB/T 18204.10-2000)对游泳池水进行检测。依据《游泳场所卫生标准》(GB 9667-1996)进行评价。结果现场检测游泳池水余氯质量浓度为0.07 mg/L和0.08 mg/L,均低于《游泳场所卫生标准》(GB 9667-1996)。游泳馆内空气质量及游泳池水卫生质量均符合《游泳场所卫生标准》(GB 9667-1996)。结论此次刺激反应事件原因为泳池临时工清洗脚垫、篦子时,误将盐酸和次氯酸钠混合配制消毒液,瞬时产生大量毒性和刺激性气体,他是本事件的唯一原因。 Objectives To investigate the cause of many people with acute chlorine gas stimulus response occurred in the indoor swimming pool,and to avoid the occurrence of similar incident in the future. Methods The authors investigated the indoor sngimming pool facilities and stimulus response patients by means of pidemiolog survey. The tests of swimming pool air quality were based on the Examination Methods for Public Places ― Part1: physical Parameters( GB / T 18204. 1- 2013),and the Examination Methods for Public Places—Part 2 :Chemical pollutants( GB / T 18204. 2- 2014),the test of swimming pool water were based on Standards for drinking water Quality( GB / T 5750- 2006),the Methods of Microbiological Examination for Water in Swimming Pool-Determination of Aerobic Bacterial Count( GB / T 18204. 9- 2000),and the Methods of Microbiological Examination for Water in Swimming Pool-Determination of Coliform Bacteria( GB / T 18204. 10- 2000). The evaluation was based on the Hygienic Standard for Swimming Place( GB 9667- 1996). Results The tests of swimming pool water residual chlorine concentration were 0. 07 and 0. 08 mg / L,which were lower than that of the Hygienic Standard for Swimming Place( GB 9667- 1996). The tests of swimming pool air quality and swimming pool water health quality were comformed to the Hygienic Standard for Swimming Place( GB 9667-1996). Conclusions The temporary member of the stuff made a faulty operation,who mixed commercial concentrated hydrochloric acid with water disinfection liquid( sodium hypochlorite solution) for mats and strainer cleaning;a violent and exothermic chemical reaction occurred immediately between a strong acid and a strong alkali,which produced enomous amount of todic and pungent chlorine gas. It was the unique cause of the event.
出处 《环境卫生学杂志》 2016年第2期157-159,共3页 JOURNAL OF ENVIRONMENTAL HYGIENE
关键词 室内游泳馆 氯气 刺激反应 indoor swimming pool chlorine gas stimulus response
  • 相关文献

参考文献8

  • 1中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB/T18204.1—2013公共场所卫生检验方法第1部分:物理因素[s].北京:中国标准出版社,2014.
  • 2中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB/T18204.2-2014公共场所卫生检验方法第2部分:化学污染物[s].北京:中国标准出版社,2014.
  • 3中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB/T5750-2006生活饮用水标准检验方法[S].北京:中国标准出版社,2007.
  • 4国家质量技术监督局.GB/T18204.9-2000游泳池水微生物检验方法细菌总数测定[S].北京:中国标准出版社,2005.
  • 5国家质量技术监督局.GB/T18204.10-2000游泳池水微生物检验方法大肠菌群测定[S].北京:中国标准出版社,2005.
  • 6国家技术监督局.GB9667-1996游泳场所卫生标准[S].北京:中国标准出版社,1996.
  • 7中华人民共和国卫生部.GBZ65-2002职业性急性氯气中毒诊断标准[S].北京:法律出版社,2004.
  • 8王洪波,郑洋,刘永泉,王秀荣,周凤武.某室内游泳馆急性氯气中毒事故调查[J].中国卫生监督杂志,2006,13(5):352-353. 被引量:1

二级参考文献2

  • 1蔡国达.一起少年游泳运动员群体氯气中毒反应事故调查报告[J].职业卫生与应急援救,1999,17(1):9-9.
  • 2蔡秀琴.一起多人氯气中毒事故调查[J].职业与健康,1995,60(4):60-60.

共引文献7

同被引文献17

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部