期刊文献+

地源吸收式热泵夏季运行方式研究

Operation Modes of Ground Source Absorption Heat Pump in Summer
下载PDF
导出
摘要 针对现有的地源吸收式热泵在夏季运行工况时所出现的系统能耗高、空调房间易结露等问题,提出将集中热源驱动的新风溶液除湿机组和地埋管夏季免费供冷相结合,构成集中热源驱动的土壤源温湿度独立控制空调系统。选取北京地区某典型办公房间,以该系统为研究对象,建立各部分的数学模型,并模拟分析了新风量对系统性能的影响。结果表明:随着单人新风量的增加,地埋管水流量基本保持不变,除湿器入口溶液流量先是急剧下降,而后基本保持不变;再生器入口溶液温度逐渐升高,而再生器耗热量先是急剧下降,而后又逐渐上升,当单人新风量为30 m^3/(h·人)时,再生器耗热量达到最低;除湿器和再生器的湿传递效率均逐渐降低。 When ground source absorption heat pump operates in summer,it spends much energy and is easy to form dew condensation in air-conditioning rooms.This paper proposes a concentrated heatresource driven ground source temperature and humidity independent control air-conditioning system,which combines concentrated heat-resource driven fresh air liquid desiccant unit with borehole free cooling in summer.Choosing a typical office room,the author takes the new system as the study object,establishes the mathematical models of all parts,and then simulates and analyses the performance of the system under different fresh air flows.The results show that,with the increase of individual fresh air flow,borehole water flow remains relatively constant,and liquid flow in the dehumidifier entrance falls rapidly at first,then remains relatively constant;the temperature of liquid in the regenerator entrance gradually increases,and the heat consumption of regenerator falls rapidly at first,then gradually increases;when individual fresh air flow is 30 m^3/(h·person),the heat consumption of regenerator reaches the lowest;the humidify effectiveness of the dehumidifier gradually decreases,as well as regenerator.
出处 《建筑节能》 CAS 2016年第5期96-100,共5页 BUILDING ENERGY EFFICIENCY
关键词 地源吸收式热泵 夏季运行工况 集中热源 溶液除湿 温湿度独立控制 ground source absorption heat pump summer operation condition concentrated heat-resource liquid desiccant temperature and humidity independent control
  • 相关文献

参考文献10

  • 1清华大学建筑节能研究中心.中国建筑节能年度发展研究报告2010[R].北京:中国建筑工业出版社,2010.
  • 2江亿,付林.一种以直燃机为水源热泵的供热方法及其装置:中国,CN02159992.0[P].2004-07-14.
  • 3张晓灵,李先庭,石文星.吸收式地源热泵在北方地区应用可行性分析[J].湖南大学学报(自然科学版),2009,36(S2):69-72. 被引量:10
  • 4王潇,付林,张世钢,赵玺灵,刘华.城市热网与浅层地热能复合型集中供热系统性能分析[J].暖通空调,2014,44(3):93-99. 被引量:2
  • 5李先庭,石文星,董俐言,等.热量倍增型热站换热机组:中国,CN201029166006.O[P].2010-11-10.
  • 6Li Xianting,Wu Wei,Zhang Xiaoling,et al.Energy saving potential of low temperature hot water system based on air source absorption heat pump[J].Applied Thermal Engineering,2012,48:317-324.
  • 7Wei Wu,Baolong Wang,Tian You,et al.A potential solution for thermal imbalance of ground source heat pump systems in cold regions:Ground source absorption heat pump[J].Renewable Energy,20 ~ 3,59:39-48.
  • 8张群力,付林,狄洪发.城市热网夏季分布式吸收式供冷方式的能效与经济性分析[J].太阳能学报,2011,32(6):855-861. 被引量:11
  • 9Wei Wu,Tian You,Baolong Wang,et al.Evaluation of ground source ab- sorption heat pumps combined with borehole free cooling[J].Energy Conver- sion and Management,2014,79:334-343.
  • 10Martin Viktoria,Goswami,D Yogi.Effectiveness of heat and mass transfer processes in a packed bed liquid desiccant dehumidifier/regenerator [J]. HVAC&Research,2000,6(1):21-39.