摘要 为了研究不同构造的钢与混凝土界面在腐蚀环境下对焊钉连接件受力性能的影响,设计了6种不同构造的钢-混凝土结合面构造形式,并考虑钢与混凝土之间的滑移效应的影响,制作了24个试验试件,其中21个试件进行了盐雾腐蚀试验,3个试件处于正常环境中.通过推出试验,测试了各个试件中焊钉的荷载-滑移关系,得到了焊钉的抗剪承载力.试验结果表明,采用钢板厚度方向上外包混凝土构造形式的试件具有更好的抗腐蚀性能,焊钉具有更高的抗剪强度,腐蚀后单钉承载力平均值为177.6kN,而在钢与混凝土界面产生初始滑动的试件具有较差的抗腐蚀性能,焊钉抗剪强度明显降低,腐蚀后单钉承载力平均值为153.3kN,比没有滑移的试件降低9.6%. In order to study the influence on static behavior of stud connector with different configuration layouts between the steel-concrete interface under corrosion environment,six types of layout were designed considering the relative slip between the steel and concrete.24 specimens including 21 specimens under corrosion environment and 3under normal environment were fabricated and used in the push-out test.The relationship between load and slip was tested during the push-out test,and the shear bearing capacity were measured.The results show that the structure with steel wrapping the concrete has a better corrosion resistance.The specimens with such layout has a higher shear resistance,and the average capacity of single stud is 177.6 kN. When the interface is slipped before the corrosion,the shear resistance is reduced compared to other specimen without pre-slip,and the average capacity of single stud after corrosion is 153.3kN which is 9.6percent less than the specimens without preslip.
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2016年第5期671-676,共6页 Journal of Tongji University:Natural Science
基金 国家"九七三"重点基础研究发展计划(2013CB036303)
关键词 焊钉 腐蚀 组合结构 盐雾试验 推出试验 stud corrosion composite structure salt spray test push-out test
  • 相关文献

参考文献12

  • 1吴冲.现代钢桥[M].北京:人民交通出版社,2006.
  • 2Viest I M. Investigation of stud shear connectors for composite concrete-steel T-beams [J]. J Am Concr Inst, 1956, 27 (8) : 875.
  • 3An Li, Cederwall Krister. Push-out tests on studs in high strength and normal strength concrete[J]. J Constr Steel Res, 1996,36 (1) 15.
  • 4Shim Chang-Su, Lee Pil-Goo, Yoon Tae-Yang. Static behavior of large stud shear connectors[J]. Eng Struct, 2004,26:1853.
  • 5Lee Pil-Goo, Shim Chang-Su, Chang Sung-Pil. Static and fatigue behavior of large stud shear connectors for steel- concrete composite bridge[J]. J Constr Steel Res, 2005,61: 1270.
  • 6Nguyen Huu Thanh, Kim Seung Eock. Finite element modeling of push-out tests for large stud shear connectors[J]. J Constr Steel Res, 2009,65 : 1909.
  • 7Ellobedy Ehab, Young Ben. Performance of shear connection in composite beams with profiled steel sheeting[J]. J Constr Steel Res, 2006,62:682.
  • 8中华人民共和国住房和城乡建设部.GB50g17-2013钢-混凝土组合桥梁设计规范[S].北京:中国计划出版社,2013.
  • 9中华人民共和国质量监督检验检疫总局.GBl0433--2002电弧螺柱焊用圆柱头焊钉[s].北京:中国标准出版社,2002.
  • 10CEN-European Committee for Standardisation. Eurocode-4 EN 1994 Design of composite steel and concrete structures. Part 1- 1 General rules for buildings[S]. Brussels: CEN-European Committee for Standardisation, 2004.

共引文献412

同被引文献15

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部