某670t/h循环流化床锅炉回料阀堵塞问题分析及处理 被引量:2

Foul block problem analysis of return valve and its treatments for a certain 670 t/h circulating fluidized bed boiler
下载PDF
导出
摘要 某循环流化床锅炉频繁发生回料阀立管堵灰,通过分析发现其主要原因为高压流化风风压低,从运行操作、设备改造和技术管理方面提出针对性措施。改进后,回料阀立管堵塞问题得以解决。 The foul block problem of return valve standpipe of a certain circulating fluidized bed boiler is frequently occurred.Through analyzing,this paper found that the main reason is the low pressure of high- pressure fluid air,and proposed some pertinence measures from the aspects of operation,equipment transformation and technical management. After that,foul block problem of return valve standpipe is solved satisfactorily.
作者 程文峰 孙健
出处 《华电技术》 CAS 2016年第3期54-57,79,共4页 HUADIAN TECHNOLOGY
关键词 锅炉 循环流化床 回料阀 立管 堵管 boiler circulating fluidized bed return valve standpipe pipe blocking
  • 相关文献

参考文献4

  • 1孙献斌,黄中.大型循环流化床锅炉技术与工程应用[M].北京:中国电力出版社,2012.
  • 2蒋敏华,孙献斌.自主知识产权大型CFB锅炉的开发研制[C]//中国电机工程学会.2006年中国电机工程学会年会论文集,2006:763-769.
  • 3DL/T1034-2006135MW级循环流化床锅炉运行导则[s].
  • 4彭小峥,陈念祖,段宏波.江西大型电站循环流化床锅炉的整治和运行情况[C]//中国电机工程学会.2006年中国电机工程学会年会报告集.北京:中国电力出版社,2006.