期刊文献+

某国际火力发电工程燃油罐防雷设计探讨

Discussion on Lightning Protection Design of Fuel Tank for a International Thermal Power Plant
下载PDF
导出
摘要 依托某国外火力发电工程,通过对比国内GB规范和美国NFPA规范在火电厂燃油区域直击雷防护方面设计标准的差异,提出了该国外发电工程燃油罐宜采用直击雷防护设计流程,建议应根据油和罐体的特征进行具体分析,确定采用何种防雷措施。 Based on an international thermal power project design work of oil tank lightning protection, This paper analyzes the difference between the Chinese design standard and American design standard in oil tank lightning protection, and put forward the international power plant fuel tank lightning protection design process. It is recommended that oil tank lighting protection design should be based on the characteristics of oil and tank which decides the lightning protection measures.
作者 宫厚良 闫琰
出处 《工程建设与设计》 2016年第6期99-101,共3页 Construction & Design for Engineering
关键词 直击雷防护 燃油灌 滚球法 折线法 NFPA lighting protection oil tank rolling ball method protective angle method NFPA
  • 相关文献

参考文献4

  • 1GB/T50064--2014交流电气装置的过电压保护和绝缘配合设计规范[S].
  • 2火力发电厂与变电站设计防火规范[S].(GB50229-2006).
  • 3GB50074-2002.石油库设计规范[S].[S].,..
  • 4NFPA780 Standardforthe InstallationofLightningProtectionSystem [S].