依托某国外火力发电工程,通过对比国内GB规范和美国NFPA规范在火电厂燃油区域直击雷防护方面设计标准的差异,提出了该国外发电工程燃油罐宜采用直击雷防护设计流程,建议应根据油和罐体的特征进行具体分析,确定采用何种防雷措施。
Based on an international thermal power project design work of oil tank lightning protection, This paper analyzes the difference between the Chinese design standard and American design standard in oil tank lightning protection, and put forward the international power plant fuel tank lightning protection design process. It is recommended that oil tank lighting protection design should be based on the characteristics of oil and tank which decides the lightning protection measures.
出处
《工程建设与设计》
2016年第6期99-101,共3页
Construction & Design for Engineering
关键词
直击雷防护
燃油灌
滚球法
折线法
NFPA
lighting protection
oil tank
rolling ball method
protective angle method
NFPA