期刊文献+

血管液态金属造影成像金属伪影校正算法研究 被引量:1

Metal Artifacts Correction Method Research about Liquid Metal Angiography
下载PDF
导出
摘要 X射线显微CT可用于研究解剖学血管网络的可视化问题。为了突出显示血管,可向血管中注入液体金属造影剂。但是由于液体金属造影剂具有较高的线性衰减系数,会在重建图像上产生放射状的金属伪影,造成血管边界不准确。为了解决这一问题,基于骨硬化校正方法,提出了新算法。实验结果表明该方法能减轻离体猪肾血管造影成像的金属伪影,提高成像质量。 Computed Tomography(CT) can be used in the visualization on the anatomical vessel networks. Liquid metal angiography can enhance the vessel networks. Because the liquid metal contrast agent has high linear attenuation coefficient, the reconstructed images usually have radial metal artifacts, which will cause the inaccurate edges of the vessels. To solve this problem, a new correction method based on bone beam-hardening correction is developed. The experiment results show that it can reduce the metal artifacts in isolated pig kidney liquid metal angiography image and improve the image quality.
出处 《CT理论与应用研究(中英文)》 2016年第2期149-157,共9页 Computerized Tomography Theory and Applications
基金 中国科学院科研装备研制项目(YZ201410) 教育部留学回国人员科研启动基金资助项目
关键词 计算机断层成像 金属伪影校正 骨模型校正 computed tomography metal artifacts correction bone beam-hardening correction
  • 相关文献

参考文献26

  • 1Qian W, Yang Y, Keqin P, et al. Liquid metal angiography for mega contrast X-ray visualization of vascular network in reconstructing in-vitro organ anatomy[J]. IEEE Transactions on Bio-medical Engineering, 2014, 61(7): 2161-2166.
  • 2Medoff BP. Image Reconstruction from Limited Data: Theory and Applications in computerized tomography[M], in Image Recovery: Theory and Application, Academic, New York, 1987, Chap. 9, 321-368.
  • 3Wang G, Snyder DL, O'sullivan JA, et al. Iterative deblurring for CT metal artifact reduction[J]. IEEE Transactions on Medical Imaging, 1996, 15(5): 657-664.
  • 4De Man B, Nuyts J, Dupont P, et al. Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm[J]. IEEE Transactions on Nuclear Science, 2000, 47(3): 977-981.
  • 5Kudo H, Saito T. Sinogram recovery with the method of convex projections for limited-data reconstruction in computed tomography[J]. Journal of the Optical Society of America A, 1991, 8(8): 1148-1160.
  • 6Zhang Y, Pu YF, Hu JR, et al. Efficient CT metal curvature diffusion[J]. Computational and artifact reduction based on fractional-order Mathematical Methods in Medicine, 2011, 2011(2011): 191-218.
  • 7Zhang Y, Pu YF, Hu JR, et al. A new CT metal artifacts reduction algorithm based on fractional-order sinogram inpainting[J]. Journal of X-ray Science and Technology, 2011, 19(3): 373-384.
  • 8Zhang Y, Pu YF, Zhang WH, et al. A novel noniterative metal artifact reduction method using coherence transport with fast marching in computed tomography[J]. International Journal of Imaging Systems & Technology, 2012, 22(4): 200-207.
  • 9KalenderWA, Hebel R, Ebersberger J. Reduction Radiology, 1987, 164(2): 576-577.
  • 10Lewitt R, Bates R. Image-reconstruction from projections 3: Projection completion methods (theory)[J]. Optik, 1978, 50(3): 189-204.

二级参考文献21

  • 1谷建伟,张丽.圆轨迹锥束CT的伪影成因和校正方法综述[C].北京:CT和三维成像学术年会论文集,2004.12-16.
  • 2Lewitt RM, Bates R H. Image reconstruction from projections( Ⅲ ): Projection completion methods [ J]. Optik,1978, 50:189-204.
  • 3Kalender W A, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants[J]. Radiology,1987, 164(2): 576 -577.
  • 4ZHAO Shiying, Douglas D. Robertson, et al. X-ray CT metal artifacts reduction using wavelets: an application for imaging total hip prostheses[ J]. IEEE Trans on Medical Imaging, 2000, 19(12) :1238 - 1247.
  • 5Medoff B Petal. Iterative convolution backprojection algorithms for image reconstruction from limited data [ J ].Journal of Optical Society of America, 1983, 73 ( 11 ):1493 - 1500.
  • 6WANG G, Donald L Snyder, Joseph A OSullivan, et al.Iterative deblurring for CT metal artifact reduction [ J ].IEEE Trans on Medical Imaging, 1996,15 (5):657 -664.
  • 7XIA Dan, Roeske John C, YU Lifeng, et al. A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy [ J ]. Brachytherapy,2005, 4(1): 18 -23.
  • 8CHEN Laigao, Liang Yun, George A Sandison, et al, A novel method for reducing high attenuation object artifacts in CT reconstructions [ J]. Proceedings of SPIE, 2002,4684: 841 - 850.
  • 9P Joseph, R Spital, A method for correction bone induced artifacts in computed tomography scanners [ J ]. J Comput. Assist. Tomogr. , 1978, 2: 100 - 108.
  • 10P Seitz, P Ruegsegger, CT bone densitometry of the anchorage of artificial knee joints [ J ]. J Comput Assist Tomogr, 1985, 9: 612 - 622.

共引文献40

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部