超短回波时间磁共振成像应用进展 被引量:7

Application progresses of ultrashort echo time MRI
下载PDF
导出
摘要 人体内所含各种组织的横向弛豫时间各不相同,有部分组织T2非常短,即短T2成分,常规MR序列无法采集相应组织的MR信号,即图像上无法显示。超短回波时间MRI作为一种可以显示短T2成分的序列,近年来得到了越来越多的应用。本文对超短回波时间MRI技术在多个系统中的应用做简要综述。 Transversal relaxation time(T2)varies from tissue to tissue in human body.Tissues with extremely short T2 relaxing components could not be shown on conventional MRI imaging.As a sequence with the capability of showing the short T2 relaxing components,ultrashort echo time(UTE)MRI is increasingly received in recent years.The application of UTE MRI in multisystem of human body were reviewed in this article.
作者 陈宁 袁慧书
出处 《中国介入影像与治疗学》 CSCD 北大核心 2016年第6期378-381,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 超短回波时间 磁共振成像 短T2成分 Ultrashort echo time Magnetic resonance imaging Short T2relaxing components
  • 相关文献

参考文献27

  • 1Robson MD, Gatehouse PD, Bydder M, et al. Magnetic reso- nance: An introduction to ultrashort TE (UTE) imaging. J Corn put Assist Tomogr, 2003,27(6) :825-846.
  • 2Du J, Bydder M, Takahashi AM, et al. Two-dimensional ultra- short echo time imaging using a spiral trajectory. Magn Reson Imaging, 2008,26(3) :304-312.
  • 3Holmes JE, Bydder GM. MR imaging with ultrashort TE (UTE)pulse sequences: Basic principles. Radiography, 2005, 11 (3) : 163-174.
  • 4Rahmer J, B6rnert P, Groen J, et al. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med, 2006,55(5) :1075-1082.
  • 5Robson MD, Bydder GM. Clinical ultrashort echo time imaging of bone and other connective tissues. NMR Biomed, 2006,19(7) : 765- 780.
  • 6Reichert IH, Benjamin M, Gatehouse PD, et al. Magnetic reso- nance imaging of periosteum with ultrashort TE pulse sequences. Magn Reson Imaging, 2004, 19(1) :99-107.
  • 7Robson MD, Gatehouse PD, Bydder GM, et al. Human imaging of Phosphoi"us in cortical and trabecular bone in vivo. Magn Re- son Med, 2004,51(5) :888-892.
  • 8Reiehert IH, Robson MD, Gatehouse PD, et al. Magnetic reso- nance imaging of cortical bone with ultrashort TE pulse se- quences. MagnReson Imaging, 2005,23(5) :611 -618.
  • 9Du J, Bydder GM. Qualitative and quantitative ultrashort-TE MRI of cortical bone. NMR Biomed, 2013,26(5):489-506.
  • 10Li S, Ma L, Chang EY, et al. Effects of inversion time on in- version recovery prepared ultrashort echo time (IR-UTE) ima- ging of bound and pore water in cortical bone. NMR Biomed, 2015,28(1) :70-78.

二级参考文献1

共引文献8

同被引文献26

引证文献7

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部