期刊文献+

血液透析用半永久颈内静脉留置导管72例 被引量:1

Hemodialysis patients with semi- permanent intrajugular indwelling catheter: a clinical analysis of 72 cases
原文传递
导出
摘要 稳定、可靠、安全的长期血管通路对维持性血液透析患者尤为重要,最佳的血管通路是自体动静脉内瘘[1],然而随着血液透析患者的日益增加,高龄、糖尿病肾病患者等自身血管条件有限、动静脉内瘘闭塞外周血管耗竭、无法建立自体动静脉内瘘的患者也随之增多,对于这些患者行半永久静脉导管也是一个很好的选择,尤其是2009年起随着Tal Palindrome新型导管的应用,
出处 《武警后勤学院学报(医学版)》 CAS 2016年第4期309-311,共3页 Journal of Logistics University of PAP(Medical Sciences)
  • 相关文献

参考文献8

  • 1NKF-K/DOQI. Clinical Practice Guidelines and Clinical Practice recommendations for 2006 Updates:Hemodialysis adequacy,peritoneal dialysis adequacy and vascular access [J]. Am J Kidney Dis, 2006, 48(Suppl 1):321-322.
  • 2张攀,叶朝阳,郑永健,戎殳,张玉强,陈静,梅长林.68例Palindrome导管的临床应用观察[J].中国血液净化,2011,10(9):483-485. 被引量:12
  • 3Raheem A, Rana AI, Mehmood SN, et al. Two years experi- ence with tunneled dialysis catheters in patients requiring haemodialysis[J]. J Pak Med Assoc, 2014, 64(7):758-761.
  • 4Stroz MJ, Nathoo B, Stroz PM. Posteriorly tunneled dialysis catheters for permanent use in cognitively impaired patients undergoing hemodialysis[J]. J Vasc Interv Radiol, 2014, 25 (10):1621-1625.
  • 5Rocha A, Castro R, Santos J. Endocarditis and spondylodisci- tis associated with tunneled cuffed hemodialysis catheters: hospitalizations with poor outcomes[J]. Int J Artif Organs, 2015, 38(4):173-177.
  • 6Sriskandarajah P, Webb K, Chisholm D, et al. Retrospective cohort analysis comparing the incidence of deep vein throm- boses between peripherally-inserted and long-term skin tunneled venous catheters in hemato-oncology patients[J]. Thromb J, 2015, 25(13):21.
  • 7Pereira K, Osiason A, Salsamendi J. Vascular access for placement of tunneled dialysis catheters for hemodialysis: a systematic approach and clinical practice algorithm[J]. J Clin Imaging Sci, 2015, 29(5):31.
  • 8Di Iorio BR, Mondillo F, Bortone S, et al. Fourteen years of hemodialysis with a central venous catheter: Mechanical long-term complications[J]. J Vasc Access, 2006, 7:60-65.

二级参考文献9

  • 1Knuttinen MG,Bobra S,Hardman J,et al.A review of evolving dialysis catheter technologies.Semin Interv Radiol,2009,26:106-114.
  • 2Swindlehurst N,Swindlehurst A,Lumgair H,et al.Vascular access for hemodialysis in the elderly.J Vasc Surg,2011,53:1039-1043.
  • 3Spector M,Mojibian H,Eliseo D,et al.Clinical outcome of the Tal Palindrome chronic hemodialysis catheter:single institution experience.J Vasc Interv Radiol,2008,19:1434-1438.
  • 4Moossavi S,Vachharajani TJ.Palindrome dialysis catheter with or without peel-away sheath.J Vasc Access,2010,11:359.
  • 5Alomari AI,Falk A.The natural history of tunneled hemodialysis catheters removed or exchanged:a single-institution experience.J Vasc Interv Radiol,2007,18:227-235.
  • 6Lok CE,Mokrzycki MH.Prevention and management of catheter-related infection in hemodialysis patients.Kidney Int,2011,79:587-598.
  • 7Tal MG.Comparison of recirculation percentage of the palindrome catheter and standard hemodialysis catheters in a swine model.J Vasc Interv Radiol,2005,16:1237-1240.
  • 8Forauer AR,Theoharis C.Histologic changes in the human vein wall adjacent to indwelling central venous catheters.J Vasc Interv Radiol,2003,14:1163-1168.
  • 9Tal MG,Peixoto AJ,Crowley ST,Denbow N,Eliseo D,Pollak J.Comparison of side hole versus non side hole high flow hemodialysis catheters.Hemodial,Int 2006,10:63-67.