摘要
目的:建立了HPLC法直接检测卡非佐米光学异构体的方法。方法:采用Chiralpak OX-H手性柱,以正己烷-异丙醇-乙醇(89∶5∶6,v/v/v)为流动相,流速为1.0 ml·min^(-1),检测波长为220 nm。结果:对映异构体、非对映异构体Ⅰ、非对映异构体Ⅱ分别在0.54~2.14μg·ml^(-1),0.11~1.80μg·ml^(-1),0.11~1.81μg·ml^(-1)范围内线性关系良好(r≥0.998);检出限为0.07~0.27μg·ml^(-1),回收率为99.6%~100.9%,RSD为1.13%~1.59%(n=9)。结论:该方法灵敏、简便、快速、准确、特异性良好,可作为卡非佐米中对映异构体和非对映异构体杂质限量的控制方法。
Objective: To establish an HPLC method for the determination of optical isomers in carfilzomib. Methods: The sample was separated on a Chiralpak OX-H column. The mobile phase consisted of n-hexane: isopropanot: alcohol (89:5:6, v/v/v) with a flow rat of 1.0 ml μg·ml-1. The detection wavelength was 220 nm. Results: The linear rang of enantiomer, diastereomer I and di- astereomer Ⅱ was 0.54-2.14 μg·ml-1,0.11-1.80 μg·ml-1 and 0.11-1.81 μg·ml-1 (r≥0. 998), respectively. The lower limit of quantification was 0.07-0.27 μg·ml-1. The recoveries of optical isomers were within the range of 99.6%-100.9% with RSD of 1.13% -1.59% ( n = 9). Conclusion : The method is sensitive, simple, fast, accurate and specific, and suitable for the study of opti- cal isomers in carfilzomib.
出处
《中国药师》
CAS
2016年第6期1094-1095,1101,共3页
China Pharmacist
基金
科技部"十二五"重大新药创制项目(编号:2014ZX09507001)