摘要
结合工程实例,介绍了钢连梁阻尼器在框架核心筒结构中的设计思路,并建立了Perform 3D模型,对使用钢连梁阻尼器的结构进行了动力弹塑性时程分析,结果表明,钢连梁阻尼器能充分耗散地震能量,为结构提供附加阻尼比,减轻结构的地震反应。
Combining with engineering examples,the paper introduces the design concept of continuous steel beam damper in frame-core wall structure,establishes Perform 3D model,and carries out dynamic time-history analysis of using continuous steel beam damper. Results show that:continuous steel beam damper can fully dissipate seismic energy,provide added damping ratio,and reduce structural seismic response as well.
出处
《山西建筑》
2016年第16期25-26,258,共3页
Shanxi Architecture
关键词
框架—核心筒
钢连梁阻尼器
动力时程分析
地震波
frame-core wall structure
continuous steel beam damper
dynamic time-history analysis
seismic wave