摘要
转辙机在运用中,会发生"吐接点"故障。通过对转辙机运用理论,减速器工作原理的分析,以及检修基地的专项试验,找到了故障原因并确定了解决方案。经过一段时间在现场验证,效果非常明显。
The output and connect error could occur in the use of switch machine.By analyzing the application theory of the switch machine and the working principle of the reducer together with special test in the maintenance base,the causes of the failure were sought out and a solution has been determined.It has been tested in the field test after a period of time that the effect is quite obvious.
出处
《铁道通信信号》
2016年第5期21-22,共2页
Railway Signalling & Communication
关键词
故障电流
反弹
摩擦联接器抱死
密贴力
Fault current
Rebound
Friction connector locking
Close stick force