期刊文献+

蓄冷型太阳能喷射制冷系统设计分析

Study of Energy-storage Solar Ejector Refrigeration System
下载PDF
导出
摘要 介绍了蓄冷型太阳能喷射制冷系统的工作原理,确定了蓄冷量的设计原则。基于郑州地区一栋200m2的住宅建筑,计算了制冷系统逐时制冷量和空调逐时冷负荷,并进行了蓄冷量的设计。研究表明,当太阳能集热面积为20m2时,该太阳能喷射系统的日设计蓄冷量为21.6kJ;与常规喷射制冷系统相比,年制冷量可提高20%左右。 The operating principle of energy storage solar ejector refrigeration system was introduced, and the design principle of cold storage capacity was developed. Based on the 200 m2 residential construction in Zhengzhou region, the hourly cooling capacity, hourly cooling load and cold storage capacity were calculated. The research showed that the cold storage capacity of solar ejector refrigeration system equals to 21.6 kJ when the solar collector area is 20 m2 , it is determined that the cooling capacity of energy storage solar ejector refrig- eration system can be improved about 20% compared with conventional system.
机构地区 中原工学院
出处 《中原工学院学报》 CAS 2016年第1期9-12,共4页 Journal of Zhongyuan University of Technology
基金 国家自然科学基金项目(51306214) 河南省高校科技创新人才计划项目(14HASTIT003) 河南省科技攻关项目(142102210286 142106000135) 河南省青年骨干教师支持计划项目(2013GGJS-114)
关键词 太阳能 蓄冷 喷射制冷系统 设计原则 solar energy energy-storage ejector refrigerating system design principle
  • 相关文献

参考文献8

二级参考文献34

  • 1王凯,吴勇,李建风,曹锋,邢子文.中高温水源热泵工质的筛选与分析[J].制冷与空调,2007,7(3):62-65. 被引量:8
  • 2索科洛夫ER,津格尔HM.喷射器[M].北京:科学出版社,1977.
  • 3JorgeI Hernandez RubenJ Dorantes.The Behavior of a Hybrid Compressor and Ejector Refrigeration System with Refrig- erants 134a and 142b .Applied Thermal Engineering,2004,24:1765-1783.
  • 4SelvarajuA ManiA.Experimental Investigation on R134a Vapourejector Refrigeration System.International Journal of Refrigeration,2006,29:1160-1166.
  • 5SankarlalT ManiA.Experimental Investigations on Ejector Refrigeration System with Ammonia.Renewable Energy,2007,32:1403-1413.
  • 6SelvarajuA ManiA.Analysis of a Vapour Ejector Refrigeration System with Environment Friendly Refrigerants .Inter- national Journal of Thermal Sciences,2004,43:915-921.
  • 7于松波.[D].天津:天津大学,2003.
  • 8JB/T7666-1995.制冷和空调设备名义工况一般规定[S].[S].,1995..
  • 9李强民.置换通风[J].现代空调,1999,(2):36-45.
  • 10邓峥 赵育根.置换通风/冷却吊顶混合系统的室内热舒适性研究[A]..2001年全国置换通风应用研讨会论文集[C].,..