摘要 孤岛检测是并网型光伏逆变器接入分布式发电系统的一个重要要求,其性能的优劣直接影响逆变器的安全可靠运行。孤岛检测的性能取决于所采用的孤岛检测策略,而其中参数的合理设置至关重要。分析了抛物线型滑模频移(PSMS)孤岛检测法的工作原理,通过对公共耦合点(PCC)电压频率在电网失压后偏移轨迹的分析,推导出不同参数下PSMS算法孤岛检测的盲区分布,并详细给出了无检测盲区的相关参数的优化过程。最后,通过实验验证了该方法的正确性及可靠性。 An important requirement for the connection of grid-connected photovohaic inverter to the distribution netw- orks is the capability of islanding detection.The advantage and disadvantage of the detection performance directly rel- ate the safe reliable operation of the grid-connected inverter.The performance of islanding detection method is subjected to the adopted strategy and related to the reasonable parameter setting.The mechanism of parabolic slide-mode frequ- ency shift(PSMS) method is analyzed.Based on analysis the frequency deviation in grid disconnected,the relationship between the non-detection zone and different parameters with PSMS method is deduced.The detailed process for para- meter optimization is presented.Finally,the experimental results verify the validity and reliability of the PSMS method.
机构地区 燕山大学
出处 《电力电子技术》 CSCD 北大核心 2016年第6期51-54,共4页 Power Electronics
基金 高等学校博士学科点专项科研基金(20121333-110007) 河北省应用基础研究计划重点基础研究项目(13964304D)~~
关键词 光伏逆变器 孤岛检测 抛物线型滑膜频移 photovohaic inverter islanding detection parabolic slide-mode frequency shift
  • 相关文献

参考文献5

  • 1Weiwei Li, Xinbo Ruan, Donghua Pan, et al.Full-feedfo- rward Schemes of Grid Voltages for a Three-phase LCL- type Grid-connected Inverter[J].IEEE Trans. on Indus- trim Electronics, 2013,60(6) : 2237-2250.
  • 2刘芙蓉,王辉,康勇,段善旭.滑模频率偏移法的孤岛检测盲区分析[J].电工技术学报,2009,24(2):178-182. 被引量:52
  • 3Teodorescu R, Liserre M, Rodrfguez P.Grid Converters for Photovohaie and Wind Power Systems[M].Hoboken :John Wiley & Sons,2011.
  • 4Liu F,Kang Y,Zhang Y,et al.Improved SMS Islanding Detection Method for Grid-connected Converters[J].IEEE Trans. on Renewable Power Generation, 2010,4 ( 1 ) : 36- 42.
  • 5丁浩,何宇,漆汉宏,魏艳君,郭小强.基于抛物线型SMS算法的孤岛检测[J].电工技术学报,2013,28(10):233-240. 被引量:18

二级参考文献30

  • 1禹华军,潘俊民.并网发电逆变系统孤岛检测新方法的研究[J].电力系统及其自动化学报,2005,17(5):55-59. 被引量:55
  • 2郑诗程,丁明,苏建徽,茆美琴,张国荣.光伏发电系统及其孤岛效应的仿真与实验研究[J].系统仿真学报,2005,17(12):3085-3088. 被引量:47
  • 3王志峰,段善旭,刘芙蓉.光伏并网系统反孤岛控制策略仿真分析[J].通信电源技术,2007,24(2):29-31. 被引量:6
  • 4郭小强,赵清林,邬伟扬.光伏并网发电系统孤岛检测技术[J].电工技术学报,2007,22(4):157-162. 被引量:110
  • 5Smith G A, Onions P A, Infield D G. Predicting islanding operation of grid connected PV inverters[J]. IEE Proc-Electr. Power Appl., 2000, 147(1): 1-6.
  • 6Ropp M. Design issues for grid-connected photovoltaic systems[D]. Georgia Institute of Technology, Atlanta, GA, Dec. 1998.
  • 7Hung G K, Chang C C, Chen C L. Automatic phase-photovoltaic inverters[J]. IEEE Transactions on Energy Conversion, 2003, 18(1): 169-173.
  • 8Yin J, Chang L, Diduch C. A new adaptive logic phase-shift alogrithm for anti-islanding protections in inverter-based DG systems[C]. IEEE 36th Power Electronics Specialists Conferenc.e, 2005: 2482-2486.
  • 9GB/T19939-2005光伏系统并网技术要求[S].中国:2005.
  • 10IEEE Std.929-2000. IEEE Recommended Practice for Utility Interface of Photovoltaic(PV) Systems[S]. Institute of Electrical and Electronic Engineers, New York: 2000.

共引文献65

同被引文献22

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部