期刊文献+

基于有限元方法的Vancouver B2型假体周围骨折治疗方法的比较 被引量:1

Comparison of different treatment methods for Vancouver type B2 fracture based on finite element analysis
下载PDF
导出
摘要 目的:用有限元分析方法对Vancouver B2型假体周围骨折不同治疗方法进行比较。方法:采集30位中老年健康志愿者左侧股骨数据,并采集M/L Taper假体,Wagner SL假体及锁定板外形数据。将所采集的数据导入有限元分析软件进行建模,模拟Vancouver B2型假体周围骨折的不同治疗方式。模拟不同负重情况下的载荷,采集各种治疗方式在不同载荷下的骨折端位移并进行统计学分析。结果:在不同载荷作用下,各组骨折端位移有统计学差异(P<0.05)。经两两比较可知,第1种治疗方式与后3种治疗方式间骨折端位移有统计学差异(P<0.05);后3种治疗方式下,骨折端位移无统计学差异(P>0.05)。结论:Wagner SL翻修假体可以用于Vancouver B2型假体周围骨折的治疗。在选择假体长度时,应尽量选择骨折线远端匹配长度大于股骨直径2倍的假体,若因其他原因无法使用理想长度的假体,则可在应用较短假体的基础上,配合使用锁定板内固定。 Objective:To compare different treatment methods for Vancouver type B2 fracture based on finite element analysis.Methods:The data of left femurs of 30 healthy aged volunteers,M/L Taper prosthesis and Wagner S/L prosthesis were collected.The data were inputted into finite element analysis software and Vancouver type B2 fracture was simulated. The offsets of fractures under different loads were recorded and analysed by statistic software. Results:Under both load conditions,significant statistical difference could be found among the four groups(P〈0.05). With pair-wised comparisons,significant statistical differences could be found between the first group and the rest 3 groups(P〈0.05),but no statistical difference could be found among the last 3 groups.Conclusion:Wagner SL prosthesis could be used for the treatment of Vancouver type B2 fractures. The optimum length of the distal fixed part should be twice longer than the diameter of the femur. If the prosthsis with ideal length could not be used,a shorter prosthesis could be considered,but a combination of locking compressed plate is recommended.
出处 《重庆医科大学学报》 CAS CSCD 北大核心 2016年第5期472-476,共5页 Journal of Chongqing Medical University
关键词 股骨 假体周围骨折 Vancouver分型 内固定 有限元分析 femur periprosthetic fractures Vancouver classification internal fixation finite element analysis
  • 相关文献

参考文献20

  • 1Broden C,Mukka S,Muren O,et al. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented,tapered,polished stem:An observational,prospective cohort study on 1,403 hips with 47 fractures after mean follow-up time of 4 years[J]. Acta Orthopaedica, 2015,86 (2) : 169-174.
  • 2Munro JT,Garbuz DS,Masri BA,et al. Tapered fluted titanium stems in the management of vancouver B2 and B3 periprosthetic femoral fractures[J]. Clinical Orthopaedics and Related Research,2014,472:590- 598.
  • 3Abdel MP,Lewallen DG,Berry DJ,et al. Pcriprosthetic femur fractures treated with modular fluted,tapered stems[J]. Clinical Orthopaedics and Related Research, 2014,472 : 599-603.
  • 4Drexler M,Dwyer T,Chakravertty R,et al. The outcome of modified extended trochanteric osteutomy in revision THA for vancouver B2/ B3 periprosthetic fractures of the femur[J]. Journal of Arthroplasty, 2014 (29) : 1598-1604.
  • 5Dzaja I,Lyons MC,McCalden RW,et al.Revision hip arthroplasty using a modular revision hip system in cases of severe bone loss [J]. Journal of Arthroplasty,2014(29) : 1594-1597.
  • 6Antoci V, Appleton P, Rodriguez EK, et al. Fixation of fractures around unstable hip implants[J]. Techniques in Orthopaedics, 2013,28 (3) :208-217.
  • 7Moazen M,Mak JH,Etchels LW,et al. Periprosthetie femoral fracture-a biomechanical comparison between vancouver type B1 and B2 1 fixation methods[J]. Journal of Arthroplasty, 2014,29 : 495-500.
  • 8Rho JY, Hobatho MC,Ashman RB. Relations of mechanical properties to density and CT numbers in human bone[J]. Med Eng Phys, 1995,17(5) :347-355.
  • 9Zdero R,Olsen M,Bougherara H,et al. Cancellous bone screw purehase:a comparison of synthetic femurs,human femurs,and finite element analysis[J]. Journal of Engineering in Medicine, 2008 (222) : 1175 - 1183.
  • 10Shah S,Kim SYR,Dubov A,et al. The biomeehanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant:cables,screws,or both?[J]. Journal of Engineering in Medicine, 2011 (225) : 845-856.

二级参考文献18

  • 1彭亮,曾小丽,白净.基于CT数据的股骨三维有限元建模方法[J].清华大学学报(自然科学版),2007,47(3):416-419. 被引量:23
  • 2Taddei F, Martelli S, Reg B, et al. Finite-Element modeling of bones from CT data: sensitivity to geometry and material uncertain- ties [ J ]. IEEE Transactions on Biomedical Engineering, 2006,53 ( 11 ) :2194-2200.
  • 3Ozan F, Yildiz H, Bora OA, et al. The effect of head trauma on fracture healing: biomechanical testing and finite element analysis [ J]. J Acta Orthop Traumatol Turc,2010,44(4) :313-321.
  • 4Arabmotlagh M, Pilz M, Warzecha J, et al. Changes of femoral periprosthetic bone mineral density 6 years after treatment with alen- dronate following total hip arthroplasty [ J ]. J Orthop Res, 2009,27 (2) :183-188.
  • 5Dudda M, Gueleryuez A, Gautier E, et al. Risk factors for early dislocation after total hip arthroplasty: a matched case-control study [J]. J Orthop Surg,2010.18(2) :179-183.
  • 6Beaupre GS. Effect of fracture gap on stability of compression plate fixation: a finite element study [ J ]. J Orthop Res ,2011,29 ( 1 ) :152.
  • 7Amin S, Kopperdhal DL, Melton LJ, et al. Association of hip strength estimates by finite-element analysis with fractures in women and men [J]. J Bone Miner Res,2011,26(7) :1593-1600.
  • 8Taddei F, Martelli S, Reggiani B, et al. Finite-element modeling of bones from CT data: sensitivity to geometry and material uncertainties [ J ]. IEEE Trans Biomed En- gi,2006,53(11) :2194-2200.
  • 9Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled [ J ]. Injury, 2003,34 ( suppl 2 ) : 11-19.
  • 10Ozan F, Yildiz H, Bora OA, et al. The effect of head trauma on fracture healing:biomechanical testing and fi- nite element analysis [ J ]. Acta Orthop Traumatol Turc, 2010,44(4) :313-321.

共引文献8

同被引文献16

引证文献1

二级引证文献3