摘要
介绍了以大量程百分表为基础的静力水准仪步进电机标定法,标定测试结果满足静力水准仪器行业标准。现场标定方法有效地得出了比例因子,减小了现场复杂环境对观测的影响。
The article introduces the step motor calibration method of static leveling instrument based on large range indicator. The calibration results meet the static level of industry standards. The locale calibration obtains the scaling factor and reduces the influence of complex environment on the observation site.