以某商业廊桥建筑为例,分析该类建筑的消防设计难点,包括消防车道、防火分区、安全疏散、灭火系统及排烟系统的设计。针对这些问题,提出调整通向室内步行街的安全出口、增加消防水池、调整消防水箱和灭火系统喷头,并进行排烟系统设计。
Taking a commercial covered bridge as an example, the fire design problems were analyzed, including fire engine channel, fire compartmentalization, safety evacuation, fire sys- tem and smoke control system design. Against the problems, suggestions on adjusting the exit to indoor commercial pedestri- an street, adding fire pool, adjusting fire water tank and fire sprinkler were made, and smoke control system design was conducted.
出处
《消防科学与技术》
CAS
北大核心
2016年第6期797-798,814,共3页
Fire Science and Technology
关键词
商业廊桥建筑
建筑防火设计
室内步行街
commercial covered bridge
building fire safety de-sign