期刊文献+

上海光源单色光荧光靶的升级改造 被引量:2

Upgrading for Monochromatic Fluorescence Screen BPMat SSRF
下载PDF
导出
摘要 光束位置探测器是同步辐射装置上的"眼睛",其中荧光靶探测器是最为直观和方便使用的一种,对于光束线的调试有着重要的作用。论文对上海光源一期研制的单色光荧光靶探测器在使用过程中存在的问题,进行了较为全面的分析总结,提出了新的设计方案,改进了单色光荧光靶的结构,压缩了该装置的体积,并且采用YAG晶体做荧光靶材,提高了探测灵敏度。改造后的单色光荧光靶探测器已经成功使用在蛋白设施五线六站新的光束线站上,取得了良好的效果。 Beam Position Monitor( BPM) is an eye of synchrotron radiation facility,Fluorescence Screen( FS)is one of the most intuitive and convenient detector. It has a very important effect to beam- line debugging. In this work,according to the defects which occurs by monochromatic fluorescence screen BPM working in SSRF Phase1,we analysed exhaustively and proposed a new design,improved the structure of Monochromatic fluorescence screen BPM,compressed the size of the detector,and taking the YAG crystal as the material of fluorescence screen. This increased the detection sensitivity. The improved Monochromatic fluorescence screen BPM is working in SSRF new lines now,and it has a positive effect and good result.
出处 《核电子学与探测技术》 CAS 北大核心 2016年第1期23-25,共3页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金的联合基金项目(U1232115)资助
关键词 单色光 荧光靶 YAG晶体 结构优化 fluorescence screen BPM Ce: YAG CVD diamond film soft x-ray
  • 相关文献

参考文献1

二级参考文献12

  • 1黎忠.X射线位置测量系统设计报告[R].2007.
  • 2Kandarakisa 1, Cavouras D. On the response of Y3A15OI2: Ce (YAG: Ce) powderscintillating screens to medical imaging X-rays[J]. Nuclear Instruments and Methods in Physics Research, 2005, A538:615-630.
  • 3Baryshevsky V G, Korzhik M V, Moroz V I, et al. YAIOs:Ce--fast-acting scintillators for detection of ionizing radiation[J]. Nucl Instr and Meth 1991, B58:291.
  • 4Moszynski M, Ludziejewski T, Wolski D, et al. Properties of YAG:Ce scintillator[J]. Nucl lnstr and Meth, 1994, A345:461.
  • 5Jiri A. Mares, Martin Nikla, Alena Beitlerova, et al. Ce3+-doped scintillators: status and properties of (Y,Lu) aluminium perovskites and garnets[J]. Nuclear Instruments and Methods in Physics Research, 2005, A537:271 275.
  • 6Nikl M. Energy transfer phenomena in the luminescence of wideband-gap scintillators[J]. Phys Sta Sol A, 2005, 202(2): 201-206.
  • 7Nikl M. Scintillation detectors for X-ray[J]. Meas Sci Tech, 2006, 17(4): R37-R54.
  • 8Pejchal J, Nikl M, Mihokova E, et al. pr3+-doped complex oxide crystal scintillators[J]. J Phys D: Appl Phys, 2009, 42(5): 155117-1-10.
  • 9Mares Jiri A, Beitlerova A, Nikl M, et al. Scintillation response of Ce-doped or intrinsic scintillating crystals in the range up to 1 MeV[J]. Rad Meas, 2004, 38(4/5/6): 353-357.
  • 10Asner D, Barbero M, Bellini V, et al. Diamond pixel modules[J]. Nuclear Instruments and Methods in Physics Research Section A, 2011,636: S 125-S 129.

共引文献5

同被引文献7

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部