期刊文献+

移动式氢复合器在福清核电站的应用

Application of Mobile Hydrogen Recombiner in Fuqing Nuclear Power Plant
下载PDF
导出
摘要 移动式氢复合器是在反应堆发生设计基准事故时,使氢气和氧气复合成水,有效地控制安全壳内的氢气浓度在安全浓度范围以内,以确保维持安全壳结构和密封性的完整性。文中介绍了移动式氢复合器在福清核电站的应用,分析了移动式氢复合器的反应原理、在设计基准事故时的消氢能力和在役检查,说明了福清核电移动式氢复合器具备对安全壳内氢气去除的能力,可大大降低氢气爆炸对安全壳的威胁。 When the reactor occurs design basis accident,a mobile hydrogen recombiner can make the hydrogen and oxygen combined into water,thus control the hydrogen concentration in the containment within safe levels effectively to ensure the sealability and integrity of containment structure.This paper introduces the application of mobile hydrogen recombiner in Fuqing nuclear power plant,and analyze the reaction principle,in-service inspection, and it's hydrogen-eliminating efficiency of mobile hydrogen recombiner.The analysis result show that mobile hydrogen recombiner in Fuqing nuclear power plant have the capability of eliminating the Hydrogen within containment,it can greatly reduce the threat of hydrogen explosion on the containment.
出处 《科技创新导报》 2016年第2期54-55,共2页 Science and Technology Innovation Herald
关键词 设计基准事故 移动式氢复合器 氢气浓度 消氢效率 Design basis accident Mobile hydrogen recombiner Hydrogen concentration Hydrogen-eliminating efficiency
  • 相关文献

参考文献3

二级参考文献5

  • 1国家核安全局.核动力厂设计安全规定[Z].北京,2004.
  • 2福建福清核电有限公司.福清核电厂1、2号机组PSAR第6.2节[Z].福建,2008.
  • 3三门核电有限公司.三门核电厂一期工程l、2号机组PSAR第6.2节[Z].浙江,2008.
  • 4台山核电有限公司.台山核电厂1、2号机组PSAR第6.2节[Z].广东,2008.
  • 5国家核安全局.福岛核事故后核电厂改进行动通用技术要求(试行)[Z].北京,2012.