摘要 低压电网漏电容易引起人身触电伤亡事故,因此研究剩余电流监控系统很有必要。为此,文章从分析当前低压电网存在的各种漏电安全隐患入手,在用电信息采集系统原有的主站、采集通道、采集设备的基础上,进行必要的软、硬件升级,提出了低压电网剩余电流监控系统的设计方案。该方案能较好地实现低压电网漏电监控,为后续研究者提供了一种全新的思路。 Electric leakage in low-voltage power network might cause electric shock injuries easily,so it is necessary to develop residual current monitoring system. Present various low voltage network leakage safety concerns are analyzed,and a design scheme for residual current monitoring system is proposed,which upgrade the hardware and software on the basis of existing master stations,acquisition channels,and acquisition equipment. The proposed scheme could achieve low voltage network leakage monitoring,providing a new train of thought for further research.
作者 吴成然 白涛
出处 《供用电》 2016年第6期77-80,共4页 Distribution & Utilization
关键词 低压电网 用电信息采集系统 剩余电流动作保护 剩余电流监控系统 分级保护 low voltage network power consumption information collection system electric leakage protection residual current monitor cascade protection
  • 相关文献

参考文献7

二级参考文献36

  • 1张功林,林韩,张榕林,陈彬.配网发展若干问题探讨[J].福建电力与电工,2009,29(4):8-9. 被引量:8
  • 2陆俭国.低压断路器和漏电保护电器的可靠性研究[J].中国工程科学,2005,7(6):36-40. 被引量:9
  • 3中华人民共和国国家和发展改革委员会.DL/T645-2007多功能电能表通信协议[S].2007.
  • 4刘洋.关于智能电表现状和前景的分析[D].香港:香港理工大学,2010.
  • 5国家电网公司.Q/GDW373--2009电力用户用电信息采集系统功能规范[s].北京:中国电力出版社,2009.
  • 6具有8KB系统内可编程Flash的8他AVR微控制器[Z].2545DAVI/07/04.
  • 7BL6523D单相多功能电能计带芯片V2.1[Z].
  • 8CodeVisionAVRVersion1.24.7用户手册[z].
  • 9国家电网公司.电力用户采集系统系列标准[s].北京:中国电力出版社,2009.
  • 10刘振亚.智能电网技术[M]{H}北京:中国电力出版社,2010.