2015年巢湖电厂2台600 MW超临界机组共计启停26次,每次机组启动过程中都消耗大量的电、水、煤、油,探讨行之有效的方法对机组启停进行控制至关重要。在保证机组安全的情况下,通过对机组启动过程优化和启动系统改造,以达到机组启动过程中的节能降耗。
Start stop times of two 600 MW supercritical units for Chaohu power plant reach 26 in 2015,every start would consume huge water,coal and oil. Chaohu power plant develops a series of feasible and effective methodology to save energy during the start-stop procedure. This paper explains the details including how to achieve the energy saving,enhance and modify the procedure of start- stop,improve the start- stop systems under the condition of safe operation.
出处
《东北电力技术》
2016年第4期10-11,共2页
Northeast Electric Power Technology
关键词
超临界机组
启动
节能
Supercritical unit
Start-up