摘要
对红沿河核电厂定子冷却水系统的功能、流程和运行方式进行说明,对定子冷却水泵无法切换至备用泵运行问题进行原因分析,并介绍了在维修和技术改进方面采取的处理措施,为其他电厂提供参考。
The function,procedure and operation mode of generator stator cooling water system in Hongyanhe nuclear power station is introduced,the reason that stator cooling water pump do not work is analyzed,the treatment and modification for this defect is introduced,it provides some references for other plants.
出处
《东北电力技术》
2016年第4期39-41,共3页
Northeast Electric Power Technology
关键词
定期试验
设计缺陷
弹簧断裂
Periodic test
Design defect
Spring fracture