送风速度对层式通风房间空气品质影响的数值模拟 被引量:4

Numerical Simulation on the Influence of Different Supply Air Velocity on Air Quality Under Stratum Ventilation
下载PDF
导出
摘要 针对层式通风空调系统,采用数值模拟方法研究了当换气次数和送风温度一定时,送风速度对室内流场、温度场和污染物CO2浓度分布的影响。研究结果表明:当设定换气次数为7次,送风温度为23℃,送风速度为0.44m/s左右时,室内热分层较好,且有利于污染物CO2的排除,室内空气质量良好。 On account of the stratum ventilation, numerical simulation method is used to research the influence of supply air velocity on the indoor temperature fields, velocity fields and the CO2 concentration fields when the value of the ventilation rate and supply air temperature is determined. The results show that when the ventilation rate is 7 times, supply air temperature is 23 ℃, and the supply air velocity is 0.44 m/s, the indoor thermal stratification is better, and it Is conducive to the excluding of pollutants CO2, indoor air quality is good.
出处 《制冷与空调(四川)》 2016年第3期350-354,共5页 Refrigeration and Air Conditioning
基金 广东省重大科技专项(2012A010800042 2012A010800018 2012A010800019) 国家自然科学基金(51108103) 亚热带建筑科学国家重点实验室开放课题(2012KB24)
关键词 层式通风 送风速度 气流组织 CO2 stratum ventilation supply air velocity air distribution CO2
  • 相关文献

参考文献8

  • 1刘向龙,金煦,娄小铁.暖通技术的现状与发展前景[J].制冷与空调(四川),2006,20(3):94-97. 被引量:12
  • 2Tian L, Lin Z, Wang Q, et al. Numerical investigation of indoor aerosol particle dispersion under stratum ventilation and under displacement ventilation[J]. Indoor and Built Environment, 2009,18(4):360-375.
  • 3许健,余跃进,张若楠.层式通风下室内气流组织特性数值仿真[J].南京师范大学学报(工程技术版),2014,14(1):39-44. 被引量:2
  • 4韩瑞端,王沣浩,郝吉波,等.层式通风不同送风方式对办公室气流组织特性的影响研究[C].走中国创造之路-2011中国制冷学会学术年会论文集,2011.
  • 5卖国仁.紊流力学[M].北京:高等教育出版社,1987.
  • 6GB50736-2012民用建筑供暖通风与空气调节设计规范[S].北京:中国计划出版社,2012:64.
  • 7ISO7730. Ergonomics of the thermal vironment-nalytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria[S]. ISO, 2005.
  • 8Standard A. 55: Thermal Environmental Conditions for Human Occupancy American Society of Heating[S]. Refrigeration and Air Conditioning Engineers, Atlanta, USA, 1992.

二级参考文献14

  • 1白静,韩书生.低温地板辐射采暖问题分析[J].山西建筑,2004,30(20):111-112. 被引量:10
  • 2李俊,孙淑凤,狄洪发,赵荣义.稳态条件下人体对个体送风的热反应研究[J].暖通空调,2004,34(12):1-6. 被引量:18
  • 3李欣,罗军.置换通风的应用前景及其适用性分析[C]//全国暖通空调制冷2002年学术年会.全国暖通空调制冷2002年学术年会资料集,2002,11:459-466.
  • 4林章,周天泰,曾志宽.层式通风-高温空调下的出路[J].化工学报,2010,40(9):82-87.
  • 5Lin Z, Chow T T, Tsang C F. Stratum ventilation-conceptual introduction [ C]//Proceedings of the lOth International Conference on Indoor Air Quality and Climate. Beijing:Indoor Air,2005:3 260-3 264.
  • 6Cho Y, Awbi H B, Karimipanah T. Theoretical and experimental investigation of wall confluent jets ventilation and comparison with wall displacement ventilation [ J ]. Building and Environment, 2008,43 ( 6 ) : 1 091 - 1 100.
  • 7Cho Y, Awbi H B, Karimipanah T. Comparison between wall confluent jets and displacement ventilation in aspect of the spreading ratio on the floor[ J ]. Proceedings of the 10th International Conference on Indoor Air Quality and Climate, Vols1-5, 2005:3 249-3 254.
  • 8中国建筑科学研究院.GB/50736--2012采暖通风与空气调节设计规范[S].北京:中国建筑工业出版社,2012.
  • 9Fanger ISO7730. Moderate Thermal Environments-determination of the PMV and PPD Indicates and Specification of the Conditions for Thermal Comfort [ S ]. Genera: International Organization for Standardzition, 1995.
  • 10高乃平,贺登峰,牛建磊.关于个性化送风若干问题的讨论[J].建筑科学,2008,24(8):103-108. 被引量:7

共引文献48

同被引文献22

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部