摘要
针对自备电站天然气调压间的采暖通风要求,并考虑土库曼斯坦国的气候类型,反复理解对比条文规范,确定了本项目的采暖、通风和自控方式,计算了该房间采暖通风系统的风量和冬季送风温度。并对送排风各环节流程的设计及装置特点进行了详细的论述。
This paper makes a detailed discussion on the ventilation system device, air distribution, etc in a project in Turkmenistan. To meet the requirements of heating and ventilation system in gas regulating room in this project, proper heating, ventilation and automatic control has been set. The air flux in the system and the air temperature in winter has also been calculated considering the local climate in Turkmenistan and the difference between the International standard and Turkmenistan standard.
出处
《制冷与空调(四川)》
2016年第3期367-370,共4页
Refrigeration and Air Conditioning
关键词
土库曼斯坦
天然气调压间
沙尘
正压
热风采暖
正常及事故排风
气流组织
Turkmenistan
Natural gas regulating room
Dust
Positive pressure
Air heating Normal and emergency ventilation
Air distribution