摘要 钢梁-钢筋混凝土柱组合结构(RCS)能够充分利用钢与混凝土材料的强度、刚度及延性等性能的优势。提出一种新型钢梁-钢筋混凝土柱全钢连接形式,采用有限元分析软件ANSYS对连接节点进行分析。结果表明:钢梁端部优先屈服,随后钢柱端部屈服,实现"强柱弱梁"的设计理念,且节点区采用全钢构式,延性耗能能力较好。分析了节点的受力机理,提出了节点设计的建议。 Steel beam and reinforced concrete column composite structure( RCS) can make full use of the advantage of strength,stiffness and ductility for steel and concrete. A new type of composite joint of steel beam and concrete column with all steel connection was proposed,and the joint was analyzed by the finite software ANSYS. The results showed that the end of steel beam yielded first and then the end of steel column,which could meet the design concept of "strong column and weak beam". The ductility and hysteretic behavior were better because of all steel connection. The mechanical mechanism was analyzed,which could provide some suggestions for joint design.
作者 王涛
出处 《钢结构》 北大核心 2016年第6期62-66,共5页 Steel Construction
关键词 钢梁-钢筋混凝土柱 全钢连接 组合节点 非线性有限元 steel beam and reinforced concrete column all steel connection composite joint non-linear finite element
  • 相关文献

参考文献9

二级参考文献25

  • 1陈忠汉.钢-砼组合结构的试验研究[J].苏州城建环保学院学报,1995,8(1):1-10. 被引量:5
  • 2白国良,姜维山,赵鸿铁,宋明秀,文双玲.钢梁─钢筋混凝土柱组合结构厂房的动力性能实测[J].工业建筑,1996,26(4):33-37. 被引量:12
  • 3[1]Shiekh T M,Deierlein G G.Beam-columu moment connec tion for composite frames: Part l. Journal of Structural Engi neering,1989,115(11):2858~2875
  • 4[2]Deierlein G G,Shiekh T M. Beam-column moment connec tion for composite frames: Part 2. Journal of Structural Engi neering,1989,115(11) :2877~2896
  • 5[3]The ASCE Task Committee on Design (riteria for Composite Structures in Steel and Concrete. (uidelines for design of joints between steel beam R. C. columns. Journal of Structural Engineering,1994,120(8):2330~2357
  • 6[4]Parra-Montesinos, G. , Weight, J. K. Seismic response of exterior RC column-to-steel beam connections. Journal of Structural Engineering, 2000, 126(10):1113~1121
  • 7[7]Criffis, L. G. Some design considerations for composite frame structures. ALSC Engineering Journal, 1986:59~64
  • 8Deierlein G G, Sheikh T M,Yura J A,et al. Beam-Column Moment Connections for Composite Frames: Part 2. Journal of Structural Engineering, ASCE, 1989,115(11): 2 877~2 896
  • 9Chou C C, Uang C M. Experimental and Analytical Studies of Two Types of Moment Connections for Composite Special Moment Frames. Report No. SSRP 98-12, San Diego:University of California, 1998
  • 10Xiao Y, Anderson J,Wu Y T.Development of Bolted Connections for Steel Reinforced Concrete Composite Structures.In: Proceedings of the 4th US-Japan Workshop on Performance Based Design of RC Structures. Toba:2002.23~24

共引文献77

同被引文献12

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部