摘要 建立了蓄热式倾斜芯型太阳能蒸馏系统,在实际天气条件下进行了实验研究,分析了给水流量和倾斜角度等对系统性能的影响。结果表明,在倾斜角度为45°时,白天的产水量最高可达4.07 L/m^2,在倾斜角度为30°时,白天的产水量最高可达3.67 L/m^2;随着给水流量的增大,太阳能蒸馏器的产水量降低;注入相变蓄热材料后夜间产水量最大可提高104%,日产水量最高可达到5.16 L/m^2,是传统式太阳能蒸馏器产水量的2.58倍。 The inclined solar distillation system is established. The experiments are performed under the condition of the practical weather outdoor. The performance of the system is analyzed with different feed water flow and inclination.The results show that,in the inclination of 45°,the daily water production can be up to 4. 07 L / m^2,and in the inclination of 30°,the daily water production can be up to 3. 67 L / m^2. The production water rate of solar distillation system is reduced with the increase of feed flow rate. The night water production could be increased by 104% after injecting PCM,and the highest water production could reach 5. 16 L / m^2. The production water is 2. 58 times of a traditional solar distillation system.
出处 《现代化工》 CAS CSCD 北大核心 2016年第6期141-144,共4页 Modern Chemical Industry
基金 国家自然科学基金项目(51209043)
关键词 相变蓄热 倾斜式 太阳能 海水淡化 PCM inclined solar desalination
  • 相关文献

参考文献6

  • 1Sampathkumar K, Senthilkumar P. Utilization of solar water heater in a single basin solar still-An experimental study [ J ]. Desalination, 2012,297:8 - 19.
  • 2Phillips O Agboola, A1-Mutaz I S, Jamel Orfi, et al. Economic investi- gation of different configurations of inclined solar water desalination systems [ J ]. Advances in Mechanical Engineering,2014,1 : 1 - 7.
  • 3Kalidasa K Murugavel, Anburaj P, SamuelHanson R, et al. Progresses in inclined type solar stills [ J ]. Renewable and Sustainable Energy Reviews ,2013,20:364 - 377.
  • 4Omara Z M, Mohamed A Eltawil, E1Sayed A E1Nashar. A new hybrid desalination system using wicks/solar still and evacuated solar water heater [ J ]. Desalination,2013,325:56 - 64.
  • 5Tabrizi Farshad Farshchi, Dashtban Mohammad, Moghaddam Hamid. Experimental investigation of a weir-type cascade solar still with built-in latent heat thermal energy storage system [ J ]. Desalination, 2010,260, ( 1/2/3 ) :248 - 253.
  • 6Mohammad Dashtban, Farshad Farshchi Tabrizi. Thermal analysis of a weir-type cascade solar still integrated with PCM storage [ J ]. De- salination ,2011,279 ( 1/2/3 ) :415 - 422.