摘要
利用热网优化运行调度软件进行虚拟管网的模拟计算,分析自管站位置、自管站数量、自管站供热面积和自管站距热源距离对自管站水力特性的影响,为含自管站的集中供热管网的水力分区提供理论基础。
The introduction of self-control heating stations into district heating network was considered in this paper. The virtual heating network was simulated by optimized operation software, influence factors of self-control heating station' hydraulic characteristics, like position, quantity, heating scope and distance to heat source were analyzed. This research could lay a solid theoretical foundation for hydraulic partition of central heating network.