从无效冷水多、水质泛锈色、夏季水温过高等方面,分析了西安市某住宅楼热水系统在运行中存在的问题,并提出了针对性的优化改造方案,经实践证明,改造后的热水系统满足了住户的使用要求。
From much ineffectual cold water,rusty water quality,higher summer water temperature and other aspects,this paper analyzed the existing problems of Xi'an a residential building hot water system in operation process,and put forward targeted optimization and transformation scheme,the practice showed that,after the transformation the hot water system met the resident requirement.
出处
《山西建筑》
2016年第19期122-123,共2页
Shanxi Architecture
关键词
住宅
热水系统
集热器
供回水管道
residential
hot water system
heat collector
supply and return water pipe