期刊文献+

肿瘤型膝关节置换后股骨-假体-胫骨复合体生物力学响应 被引量:5

Biomechanical responses of the femur-prosthesis-tibia complex after tumor-type artificial knee replacement
下载PDF
导出
摘要 目的研究肿瘤型铰链式膝关节置换术后股骨-假体-胫骨复合体正常站立状态下的生物力学响应,探讨病人术后发生股骨穿孔的原因,为肿瘤型铰链式人工膝关节假体的优化设计与制造提供理论基础。方法兼顾CT及三维光学扫描数据建立股骨远端骨肉瘤瘤段切除肿瘤膝关节置换后的病人股骨-假体-胫骨有限元模型,并进行相关有效性验证,从而进一步分析人体站立状态下股骨-假体-胫骨复合体的应力分布及应力遮挡现象。结果 (1)在站立加载状态下,相对胫骨,股骨的应力明显更大且集中分布趋势显著,股骨前1/3区域应力较大,呈现应力遮挡效应。(2)由于模型基于临床病人几何及骨质特征建立,股骨应力集中位置与临床中病人股骨穿孔位置接近,表明在施加自身重力状态下可能发生与病人病症一致的股骨损伤行为。结论肿瘤型铰链式膝关节假体植入后,由于假体髓针深入骨髓腔,正常站立状态下亦对骨髓腔产生一定的压力;由此产生的应力遮挡效应以及假体髓针与特定骨髓腔的匹配情况均可能引起股骨应力集中,从而将可能引起股骨开裂,甚至穿破,影响手术质量。建议术前优化假体设计以减轻或避免此类现象,从而减少术后患者的并发症发生率。 Objective By studying biomechanical responses of the femur-prosthesis-tibia complex under normal standing condition after tumor-type hinged knee arthroplasty,to investigate the cause of femoral perforation in patients after knee arthroplasty,so as to provide a theoretical basis for optimal design and manufacturing of tumortype hinged artificial knee prosthesis. Methods By coupling CT and 3D optical scanning,the finite element model of the subject-specific femur-prosthesis-tibia complex was established and was validated regarding its availability,so as to analyze stress distribution and stress shielding phenomenon of the complex in standing position. Results( 1) Under the loading state of standing,the stress on the femur was significantly larger than that on the tibia,and presented an evident concentration phenomenon. The proximal 1 /3 of femoral shaft presented a larger stress,with a stress shielding effect.( 2) As the model was based on geometry and bone characteristics of the patient in clinic,the location of femur stress concentration was close to that of femur perforation in the patient,which indicated that femur injury behavior might occur when its own gravity was applied such as the patient condition. Conclusions After implantation of the tumor-type hinged artificial knee prosthesis,the prosthesis marrow needle goes deep into marrow cavities,which brings certain pressure to the marrow cavities even under normal standing condition. The produced stress shielding effect and the match of the prosthesis marrow needle to the marrow cavity are all likely to cause stress concentration on the femur,even make femur crack or perforation,and eventually affect the surgery quality. Thus,the prosthesis design should be carefully optimized before surgery in order to reduce or avoid such phenomenon that is related to the postoperative complication rate.
出处 《医用生物力学》 EI CAS CSCD 北大核心 2016年第3期235-239,246,共6页 Journal of Medical Biomechanics
基金 国家自然科学基金项目(51405150)
关键词 肿瘤 膝关节置换 应力分布 应力遮挡 有限元分析 生物力学响应 Tumor Knee arthroplasty Stress distribution Stress shielding Finite element analysis Biomechan ical response
  • 相关文献

参考文献16

  • 1赵思桥,郭征,王瑧,范宏斌,付军,吴智钢,石磊.肿瘤型膝关节假体置换术后近期再次手术的原因分析[J].中国矫形外科杂志,2014,22(15):1375-1379. 被引量:9
  • 2Okita Y, Tatematsu N, Nagai K, et al. Compensation by nonoperated joints in the lower limbs during walking after endoprosthetic knee replacement following bone tumor resection [J]. J Clin Biomech, 2013, 28(8): 898-903.
  • 3Jeys LM, Kulkarni A, Grimer R J, et aL Endoprosthetic reconstruction for the treatment of musculoskeletal tumors of the appendicular skeleton and pelvis [ J ]. J Bone Joint Surg Am, 2008, 6: 1265-1271.
  • 4Balke M, Ahrens H, StreitbLirger A, et aL Modular endo- prosthetic reconstruction in malignant bone tumors: Indica- tions and limits [ J]. Recent Results Cancer Res, 2009, 179 : 39-50.
  • 5Biau D, Faure F, Katsahian SJ, et aL Survival of total knee replacement with a megaprosthesis after bone tumor resection [J]. J Bone Joint Surg Am, 2006, 88(6) : 1285- 1293.
  • 6Wirganowicz PZ, Eckardt JJ, Dorey F J, et aL Etiology and results of tumor endoprosthesis revision surgery in 64 patients[J]. Clin Orthop, 1999, 358: 64-74.
  • 7Ural A, Bruno P, Zhou B, et aL A new fracture assess- ment approach coupling HR-pQCT imaging and fracture mechanics-based finite element modeling [ J]. J Biomech 2013, 46(7) : 1305-1311.
  • 8Ascenzi M-G, Kawas NP, kutz A, et al. Individual-specific multi-scale finite element simulation of cortical bone of human proximal femur [J]. J Comput Phys, 2013, 244: 298-311.
  • 9王昊森,郝智秀,林剑浩,李志昌.基于有限元方法的全髋关节假体个体化选型分析[J].医用生物力学,2014,29(3):219-226. 被引量:6
  • 10姜海波,葛世荣.骨水泥与置换髋关节的界面力学计算[J].机械工程材料,2008(1):24-26. 被引量:6