摘要 为研究T型钢连接梁柱节点的抗火性能及破坏模式,使用垂直抗火试验炉,采用恒载升温方式,对4个十字形足尺钢框架T型钢半刚性节点进行抗火试验。试验主要考察T型钢厚度、高强螺栓直径和楼板等因素对节点抗火性能的影响。试验过程中对节点的温度发展和变形情况进行测量,并对钢梁的位移-时间曲线进行分析。结果表明:火灾下T型钢节点的破坏模式主要取决于T型钢和高强螺栓间的相对承载力,承载力相对弱的部分将先发生破坏;混凝土楼板可以较大幅度地提高节点的抗火性能,高强螺栓直径和T型钢壁厚对节点的抗火性能影响不显著;T型钢节点刚度和抗弯承载力在温度升高到500℃~650℃之前无明显变化,之后迅速下降。 To understand their fire resistance and failure mode, an experimental study was performed on four full-scale cross steel beam-column T-stub joints by using a vertical furnace. The load was kept constant during the fire. The key parameters investigated include the thickness of the T-stub, the diameter of the bolts, and the floor on beams. The temperature distribution and the deformation of the T-stub joints in fire were measured through the test. The deformation-curves of the beams are then discussed. The results show that the failure modes of the T-stub joints in fire depend on the relative bearing capacity between the T-stub and bolts, and the damage occurs in the weaker of the two. The floor can greatly enhance the fire-resistance of the T-stub joints, while the thickness of the T-stub and the diameter of the bolts have little influence on the fire performance of the joints. The fire-resistance and stiffness of T-stub joints decrease sharon after 500℃-650℃.
出处 《工程力学》 EI CSCD 北大核心 2016年第7期136-143,共8页 Engineering Mechanics
基金 国家自然科学基金项目(51178098 51378105) 江苏高校优势学科建设工程项目(1105007001) 江苏省产学研前瞻性联合研究项目(BY2012200)
关键词 T型钢 半钢性 火灾试验 节点 温度 位移 T-stub semi-rigid fire experiment joints temperature displacement
  • 相关文献

参考文献17

  • 1CECS200:2006,建筑钢结构防火技术规范[S].北京:中国计划出版社,2006.
  • 2Jabria K S,Burgess I W,Lennon T,et al.Moment-rotation-temperature curves for semi-rigid joints[J].Journal of Constructional Steel Research,2005,61(3):281―303.
  • 3Silva D L S,Santiago A,Real P V,et al.Behaviour of steel joints under fire loading[J].Steel and Composite Structures,2005,5(4):485―513.
  • 4Mao C J,Chiou Y J,Hsiao P A,et al.Fire response of steel semi-rigid beam-column moment connections[J].Journal of Constructional Steel Research,2009,65(6):1290―1303.
  • 5Yahyai M,Daryan A S.The study of welded semi-rigid connections in fire[J].Structural Design of Tall and Special Buildings,2013,22(10):783―801.
  • 6Hu G,Engelhardt M.Studies on the behavior of steel single plate connections in fire[J].Structural Engineering International:Journal of the International Association for Bridge and Structural Engineering(IABSE),2012,22(4):462―469.
  • 7Shuyuan L,Zhaohui H,Mizi F.Analysis of end-plate connections at elevated temperatures[J].Steel and Composite Structures,2013,15(1):81―101.
  • 8王卫永,董毓利,李国强.外伸端板节点火灾行为的试验研究和理论分析[J].哈尔滨工业大学学报,2006,38(12):2125-2128. 被引量:14
  • 9郝淑英,董金浩,叶金铎.火灾下加劲肋对梁柱外伸端板连接性能的影响[J].工程力学,2010,27(8):152-155. 被引量:3
  • 10李国强,李侥婷,楼国彪.梁端受框架约束的平端板连接组合节点抗火性能试验研究[J].建筑结构学报,2011,32(4):125-133. 被引量:5

二级参考文献40

共引文献23

同被引文献102

引证文献11

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部