期刊文献+

Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion 被引量:2

Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion
原文传递
导出
摘要 Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model. Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; M R and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement. Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1 -week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.82 l ) were observed. Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children. Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model. Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; M R and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement. Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1 -week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.82 l ) were observed. Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1584-1591,共8页 中华医学杂志(英文版)
基金 grants from the National Natural Science Foundation of China,Outstanding Scientific Fund of Shengjing Hospital
关键词 Femoral Anteversion HIP Magnetic Resonance Imaging PIGLET Three-dimensional Fast Spin Echo Cube Femoral Anteversion Hip Magnetic Resonance Imaging Piglet Three-dimensional Fast Spin Echo Cube
  • 相关文献

参考文献2

二级参考文献1

  • 1Dr J. S. Kim,T. S. Park,S. B. Park,J. S. Kim,I. Y. Kim,S. I. Kim. Measurement of femoral neck anteversion in 3D. Part 1: 3D imaging method[J] 2000,Medical & Biological Engineering & Computing(6):603~609

共引文献18

同被引文献15

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部