摘要
介绍了低压谐波抑制装置的工作原理,分析了有源滤波器的实现和系统控制方法,并对谐波抑制装置进行了试验验证。试验结果表明,谐波抑制装置实现了动态谐波抑制和无功补偿,对于提高电能品质、节能降耗、降低电力基础设施投资等方面具有较大意义。
This paper introduced the working principle of low voltage harmonic suppression device,and analyzed the realization of active filter and system control method. The experiment was designed to verify the active harmonic suppression device. The experimental results show that the active harmonic suppression device realizes the dynamic harmonic suppression and reactive compensation. It has an important significance for improvements of power quality,energy saving and consumption reducing,and decrease of power infrastructure investment.
出处
《现代建筑电气》
2016年第6期28-30,共3页
Modern Architecture Electric
关键词
低压有源谐波抑制装置
静止无功发生器
无功补偿
间接电流控制
low voltage harmonic suppression device
static var generator(SVG)
reactive compensation
indirect current control