摘要
本文基于辽宁省3个建筑能耗监管平台对分别设有VRV及集中式空调系统的12栋办公建筑进行了建筑电耗分析。结果表明:VRV空调系统及集中式空调系统都存在很大的节能潜力;VRV空调系统随室内冷负荷变化的可调节性要好于集中式空调系统;最后指出影响两类空调系统节能运行的主要因素。
This paper analyzed the operational power consumption of 12 office buildings equipped with VRV and centralized air-conditioning systems in Liaoning Province according to the monitoring data derived from three building energy monitoring and management systems. Results show that both air-conditioning systems had great potential for energy saving,and the adjustability of VRV air-conditioning system was better than that of centralized air-conditioning system. Finally,the main effective factors of energy saving in the operation process of two airconditioning systems were pointed out.
出处
《建筑科学》
CSCD
北大核心
2016年第6期108-115,共8页
Building Science
基金
大连市科技计划项目"旧有建筑空调系统优化控制节能改造"(2015E11SF052)
关键词
VRV空调系统
集中式空调系统
建筑能耗监管平台
建筑能耗分析
Variable Refrigerant Volume(VRV) air-conditioning system
centralized air-conditioning system
building energy monitoring and management system
building energy analysis