超声弹性成像定量分析诊断BI-RADS 4类乳腺肿块良恶性 被引量:23

Ultrasound elastography imaging quantitative analysis techniques for diagnosing benign and malignant breast neoplasms of BI-RADS 4
下载PDF
导出
摘要 目的 探讨超声弹性成像(UE)定量分析鉴别乳腺影像和报告数据系统(BI-RADS)4类乳腺肿块良恶性的应用价值。方法 对86例经超声诊断为BI-RADS 4类乳腺肿块的患者行UE检查,检测弹性指数(EI)和弹性指数差(EID)。以病理结果为金标准,绘制ROC曲线,评价EI、EID判断乳腺肿块良恶性的效能。结果 86例肿块经病理证实良性44例,恶性42例。ROC曲线分析显示,EI、EID鉴别BI-RADS 4类乳腺肿块良恶性的曲线下面积(AUC)分别为0.81、0.95。以EID≥2.5为临界值,敏感度、特异度、准确率、阳性预测值、阴性预测值分别为92.86%(39/42)、90.91%(40/44)、91.86%(79/86)、90.70%(39/43)、93.02%(40/43);以EI≥3.6为临界值,敏感度、特异度、准确率、阳性预测值、阴性预测值分别为61.90%(26/42)、86.36%(38/44)、74.42%(64/86)、81.25%(26/32)、70.37%(38/54)。EID的诊断准确率、敏感度及阴性预测值均高于EI(χ~2=9.33、11.50、7.80,P均〈0.05),二者特异度及阳性预测值差异无统计学意义(χ~2=0.45、1.42,P均〉0.05)。结论 UE定量分析参数EI、EID均有助于鉴别乳腺BI-RADS 4类肿块的良恶性,且EID诊断准确率更高。 Objective To explore the application value of quantitative analysis with ultrasound elastography (UE) to identify benign and malignant breast masses of breast imaging reporting and data system (BI-RADS) 4. Methods UE examinations were performed on 86 patients with BI-RADS 4 breast masses. The elastic index (EI) and elastic index difference (EID) were measured and calculated. Taking pathological results as the gold standard, the ROC curve was obtained. The efficacities of EI and EID in determining benign and malignant breast masses were evaluated. Results Among 86 cases, there were 44 cases of pathologically proved benign masses and 42 cases of pathologically proved malignant masses. ROC curve showed that the areas under the curve (AUC) of EI and EID for identifying benign and malignant BI-RADS 4 breast masses was 0.81 and 0.95, respectively. With the threshold of EID≥2.5, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value were 92.86% (39/42), 90.91% (40/44), 91.86% (79/86), 90.70%//00 (39/43) and 93.02% (40/43), respectively. With the threshold of EI≥3.6, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value were 61.90% (26/42), 86.36% (38/44), 74.42% (64/86), 81.25% (26/32) and 70. 37% (38/54), respectively. The accuracy, sensitivity and negative predictive value of EID were higher than those of EI (X2 = 9.33, 11.50, 7.80, all P〈0.05). No statistical differences of specificity and positive predic- tive value between EID and EI (2 20. 45, 1.42, both P〉0.05). Conclusion EI and EID in the quantitative analysis with UE are beneficial for identifying benign and malignant BI-RADS 4 breast masses, and the accuracy of EID is higher.
出处 《中国医学影像技术》 CSCD 北大核心 2016年第7期1065-1069,共5页 Chinese Journal of Medical Imaging Technology
关键词 乳腺肿瘤 超声检查 弹性成像技术 Breast neoplasms Carcinoma Ultrasonography Elasticity imaging techniques
  • 相关文献

参考文献13

  • 1陈可欣,何敏,董淑芬,王继芳.天津市女性乳腺癌发病率死亡率和生存率分析[J].中华肿瘤杂志,2002,24(6):573-575. 被引量:79
  • 2Gazinska P, Grigoriadis A, Brown JP, et al. Comparison of bas- al-like triple-negative breast cancer defined by morphology, im- munohistochemistry and transcriptional profiles. Mod Pathol, 2013,26(7) :955-966.
  • 3Ophir J, Cespedes I, Ponnekanti H, et al. Elastography: A quantitative method for imaging the elasticity of biologic tissues. Ultrasonic Imaging, 1991,13(2) :111 134.
  • 4Wojcinski S, Farrokh A, Weber S, et al. Muhicenter studdy of ultrasound real-time tissue elastography in 799 cases for the as- sessment of breast lesions: Improved diagnostic performance by combining the BI-RADS-US classification system with sonoelas- togrraphy. Ultraschall Med, 2010,31(5) :484-491.
  • 5智慧,肖晓云,杨海云,吴欢,罗葆明.BI-RADS诊断标准与UE结合对乳腺肿物诊断价值的探讨[J].中国超声医学杂志,2011,27(4):310-312. 被引量:34
  • 6Evans A, Whelehan P, Thomson K, et al. Differentiating benign from malignant solid breast masses: Value of shear wave elastog- raphy according to lesion stiffness combined with greyscale ultra- sound according to BI-RADS classification. Br J Cancer, 2012, 107(2) :224 229.
  • 7Sadigh G, Carlos RC, Neal CH, et al. Ultrasonographic differen tiation of malignant from breast lesions: A meta-analytic compari-son of elasticity and BIRADS scoring. Breast Cancer Res Treat, 2012, 133(1) :23 35.
  • 8吴秀平,宋庆华,杜毅力.二维超声、多普勒超声及弹性成像鉴别诊断乳腺肿块[J].中国医学影像技术,2011,27(5):971-974. 被引量:45
  • 9Rudnko OV, Sarvazyan AP, Emelianov SY. Acoustic radiation force and streaming induced by focused nonlinear ultrasound in a dissipative medium. J Acoust Soc Am, 1996,99(5):2791-2798.
  • 10Fatemi M, Greenleaf JF. Ultrasound-stimulated vibroacousticspectrography. Science, 1998,280(5360) :82 -85.

二级参考文献41

共引文献216

同被引文献156

引证文献23

二级引证文献201

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部