摘要 应用ABAQUS软件建立局部火灾作用下PEC柱—钢梁组合平面框架的温度场和抗火性能分析模型,模型得到相关试验数据的验证。应用验证后的模型分析火灾高温下PEC柱—钢梁组合框架的失效模式、PEC柱内力变化规律和结构变形特征等,并分析火灾发生位置对PEC框架结构耐火性能的影响。结果表明:在不同的保护层厚度和荷载情况下,PEC柱—钢梁组合框架会出现梁先失效和柱先失效两种不同的失效模式;柱先失效模式会导致结构整体的破坏,梁先失效模式只会引起结构局部发生破坏;框架受火面积越大,受火柱的轴压比和受火梁的荷载比越大,框架的耐火极限越短。 By using ABAQUS program,finite element model was established to calculate the temperature field distribution in the frame members and the fire resistance behavior of PEC columns -steel beam composite plane frame under local fire condition,which was validated by some test data.The effect of fire location on the fire resistance of the frame structure,failure mode of the frame,change regulation of the internal force in the PEC column and the deformation behavior were analyzed.Base on the research work,it can be seen that columns failure mode and beam failure mode will appear when the plane frame under the different load condition and fire retardant coating thickness.Columns failure mode will lead to overall structural failure,but only local damage appeared in the beam failure mode.Main influencing factors of the fire resistance limit of the frame is axial load level of columns and beams.Increasing of loading level of the columns and beams,as well as the region exposed to fire will cause the drop of fire resistance of the frame.
作者 王宇 毛小勇
出处 《消防科学与技术》 CAS 北大核心 2016年第7期887-891,共5页 Fire Science and Technology
基金 国家自然科学基金项目(50708062) 江苏省"六大高峰"人才项目(2012-5Z-004) 江苏省高校自然科学基金重大项目(14KJA560003)
关键词 PEC柱框架 局部火灾 有限元模型 失效模式 耐火极限 轴力 弯矩 挠度 PEC columns local fire finite element model failure mode fire resistance axial force bending moment deflection
  • 相关文献

参考文献9

二级参考文献65

  • 1肖建庄,谢猛,潘其健.高性能混凝土框架火灾反应与抗火性能研究[J].建筑结构学报,2004,25(4):1-7. 被引量:20
  • 2陆洲导,朱伯龙,周跃华.钢筋混凝土简支梁对火灾反应的试验研究[J].土木工程学报,1993,26(3):47-54. 被引量:64
  • 3姚亚雄,朱伯龙.钢筋混凝土框架结构抗火试验研究[J].同济大学学报(自然科学版),1996,24(6):619-624. 被引量:38
  • 4隋炳强,董毓利,王卫永,王彦超.钢框架中柱刚节点抗火性能试验研究[J].东南大学学报(自然科学版),2007,37(4):651-655. 被引量:13
  • 5Wald F, Simoes da Silva L, Moore D B. Experimental behavior of a steel structure under natural fire [J]. Fire Safety Journal, 2006, 41 (7): 509- 522.
  • 6Kodur V K R, Wang T C, Cheng F P. Predicting the fire resistance behavior of high strength concrete column [J]. Cement & Concrete Composite, 2004, 26(2): 141-153.
  • 7Lim L, Buchanan A, Moss E Numerical modeling of two-sway reinforced concrete slabs in fire [J]. Engineering Structures, 2004, 26(8): 1081-1091.
  • 8CECS200:2006,建筑钢结构防火技术规范[S].北京:中国计划出版社,2006.
  • 9ISO 834-1, Fire resistance tests-elements of building construction-Part 1: General requirements [S]. Geneva: International Standard ISO 834, 1999.
  • 10Eurocode 2. BSEN1992-1-2: 2004, Design of concrete structures-Partl-2: General rules: Structural fire design IS]. Brussels (Belgium): European Committee for Standardization, 2004.

共引文献68

同被引文献27

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部